Talanta

A G4-nanotweezer/DNA tetrahedron-confined dual-mode ECL/SERS biosensor for ultrasensitive rabies viral RNA detection via CRISPR-Cas12a-regulated hemin switching.

Yuanxun Gong, Xiao Huang, Hanyi Nong, Haozhen Ren, Yue Huang, Qianli Tang, Kai Zhang, Xianjiu Liao

Guangxi Key Laboratory of Artificial Intelligence for Genetic Diseases of Long-dwelling Nationalities, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. · Engineering Research Center of Guangxi Higher Education Institutions for Precise Genetic Testing of Long-Dwelling Nationalities, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China.

Key points

From the paper's conclusion
  • We developed a DNA tetrahedron-confined G4-nanotweezer biosensor combining electrochemiluminescence (ECL) and surface-enhanced Raman scattering (SERS).

Abstract

Reliable detection of low-abundance rabies viral RNA (RABV RNA) requires sensitive readouts that tolerate interfacial and matrix-associated signal variation. We developed a DNA tetrahedron-confined G4-nanotweezer biosensor combining electrochemiluminescence (ECL) and surface-enhanced Raman scattering (SERS). A Ti3C2/CsPbBr3@PDA@AuNPs nanocomposite (PAM) provided the dual-mode transducing interface, with hemin serving as both an ECL-modulating species and a SERS reporter. CsPbBr3 served as the ECL emitter, PDA improved interfacial stability, AuNPs provided SERS hotspots and DNA anchoring sites, and Ti3C2 acted as a conductive scaffold. Without target RNA, the bridging strand (ST) promoted a closed G4/hemin configuration, producing high SERS and low ECL signals. RABV RNA-triggered binding-induced isothermal amplification generated single-stranded DNA activators for CRISPR-Cas12a. Subsequent ST cleavage prevented nanotweezer closure and reduced interfacial hemin enrichment, producing an ECL-on/SERS-off response. Control experiments linked hemin-associated ECL modulation to the interfacial configuration without establishing a unique microscopic quenching pathway. The ratiometric signal R = IECL/ISERS enabled quantification over 1 aM to 50 fM. Additional low-concentration calibration yielded an estimated detection limit of 0.0675 aM by blank-threshold inverse prediction, extrapolated below the lowest measured nonzero standard of 0.10 aM. At 10 fM, matched-channel comparisons gave ratiometric relative standard deviations of 2.49% for ten successive readings and 2.87% across six independently prepared electrodes. In tenfold-diluted human serum at 10 fM, the ratio showed an 8.20% absolute deviation from phosphate-buffered saline, indicating partial matrix-effect compensation. This shared-reporter architecture links programmable DNA switching to complementary optical readouts for sensitive ratiometric viral RNA analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers