A multi-modal mass spectrometric approach for lipid analysis enabled by online fractionation of complex mixtures in a solid-phase extraction cartridge.
Octavion Spears, Alexander Grooms, Benjamin Burris, Abraham K Badu-Tawiah
Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA. badu-tawiah.1@osu.edu.
Key points
From the paper's conclusion- Together, the three elution steps enabled 93.0% of the lipids in the mixture to be detected, with overall improvement in signal intensities.
Abstract
This study aimed to develop a direct infusion analytical platform for analyzing complex lipid mixtures using a solid-phase extraction (SPE) cartridge. The SPE cartridge was developed in-house and coupled to a contained-electrospray ionization (cESI) source, which enabled online fractionation of lipids followed by real-time mass spectrometry (MS) analysis of eluates. The SPE cartridge was packed with a silica sorbent. We used multiple solvents with varying polarities to sequentially elute and characterize different lipids. To stabilize the electrospray signal derived from nonpolar organic solvents, our SPE-cES-MS platform utilized a co-axial spray system that allowed an ammonium acetate containing lipase enzyme to be delivered from a second electrospray capillary. In its fullest implementation, the SPE-cESI-MS platform was applied to fractionate a sample mixture containing 18 different lipids using hexane, ethanol, and water for sequential elution from the silica sorbent. Together, the three elution steps enabled 93.0% of the lipids in the mixture to be detected, with overall improvement in signal intensities. In contrast, without the miniaturized SPE front-end, direct analysis of the 18-component lipid mixture resulted in the detection of 85.7% of the lipids. The solvents employed were optimized by evaluating their selectivity for polar and nonpolar lipids. The limits of detection associated with the elution of nonpolar lipids (e.g., trilinolein) from the polar silica surface were determined to be 0.62 µM and 0.84 µM for the elution of polar oleic acid from the same sorbent. This work represents a rapid and affordable analytical approach for analyzing complex lipid mixtures in situations where conventional chromatography cannot be used, including analysis on a portable mass spectrometer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Environmentally Friendly LC-MS/MS Method for the Determination of Etrasimod in Human Plasma via Advanced Phospholipid Matrix Removal.Pharmaceuticals (Basel, Switzerland) · 2026
- Micro-flow LC- drift tube IMS-MS with high-resolution demultiplexing for enhanced lipidome coverage of volume-limited biological samples.Talanta · 2026
- Optimization of untargeted lipidomics analysis of human plasma after Dangguijakyak-san administration.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Optimizing nanoLC-TIMS-TOF and lipidomics sample preparation for low volume of plasmaScientific Reports · 2026
- TiO2-modified paper spray mass spectrometry for selective phospholipid removal in milk and plasma.Talanta · 2026
- Systematic evaluation of SPE cartridges in a 12-second SPE-IM-MS workflow for untargeted intracellular metabolomicsScientific Reports · 2026