Optimizing nanoLC-TIMS-TOF and lipidomics sample preparation for low volume of plasma
Klidel Fae Rellin, Lisa Abel, Aiko Barsch, Michael A. Witting
Aristotle University of Thessaloniki · University of Bremen
Key points
From the paper's conclusion- Here, we evaluated a nanoflow liquid chromatography workflow coupled with trapped ion mobility spectrometry and time-of-flight mass spectrometry (nanoLC-TIMS-TOF) for positive ion lipid profiling from as little as 1 µL of plasma.
Abstract
Abstract Lipidomics provides critical insights into disease mechanisms, biomarker discovery, and precision medicine, but conventional LC-MS workflows often require sample volumes that limit their application in minimally invasive studies. Here, we evaluated a nanoflow liquid chromatography workflow coupled with trapped ion mobility spectrometry and time-of-flight mass spectrometry (nanoLC-TIMS-TOF) for positive ion lipid profiling from as little as 1 µL of plasma. Two commonly used single-phase extraction protocols, MeOH: MTBE and IPA: H₂O, were scaled to microsample volumes using NIST ® SRM ® 1950 plasma. The effects of plasma input volume and mobile-phase ammonium formate concentration (2, 5, and 10 mM) on feature detection and chromatographic performance were evaluated. Descriptive comparisons revealed extraction-, volume-, and buffer-associated differences in the detected feature profiles, while putative lipid annotations were evaluated using MS/MS and ion-mobility information, where available. The optimized workflow enabled broad positive ion lipid class profiling and detection of low intensity features from only 1 µL of starting material. The 1 µL extracts retained the dominant annotated lipid classes observed at higher input volumes, although profiling depth and feature distributions remained dependent on plasma input volume. Among the tested mobile phase conditions, 5 mM ammonium formate produced the highest detected feature count while limiting pressure drift during extended acquisition. These results support the feasibility and practical scalability of positive ion nanoLC-TIMS-MS lipid profiling for sample-limited applications under the evaluated conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Micro-flow LC- drift tube IMS-MS with high-resolution demultiplexing for enhanced lipidome coverage of volume-limited biological samples.Talanta · 2026
- Optimization of untargeted lipidomics analysis of human plasma after Dangguijakyak-san administration.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Multi-omic analyses of the same sample using metabolomics, lipidomics, proteomics, phosphoproteomics, and glycoproteomics.Chemical communications (Cambridge, England) · 2026
- RPLC- and HILIC-based non-targeted metabolomics workflow for blood microsamplesMetabolomics · 2026
- LC-MS/MS-Based Untargeted Lipidomics Using MS-DIAL.Methods in molecular biology (Clifton, N.J.) · 2026
- Fast and Scalable Sample Preparation for Integrated Metabolome and Exposome-Wide Association Studies (MWAS/ExWAS).Analytical chemistry · 2026