From the paper's conclusion- The Actiwatch recorded significantly greater scotopic ( < 3 lux) durations compared to other sensors (p < 0.05 for all).
Abstract
This study compared five wearable sensors (VEET, Clouclip, Actiwatch, ActLumus, and GENEActiv) for quantification of myopia-related environmental exposures. Thirty participants (27.8 ± 7.0 years) simultaneously wore two spectacle-mounted and three wrist-worn sensors for one day while maintaining a detailed activity log. Data were binned by viewing distance (near: 15- < 60 cm, intermediate: 60- < 100 cm, far: ≥100 cm) and illumination (scotopic: <3 lux, mesopic: 3 to < 30 lux, indoor photopic: 30 to <1000 lux, outdoor photopic: ≥ 1000 lux). The VEET recorded significantly more near and intermediate time than the Clouclip (p < 0.001). Activity logs yielded significantly lower near viewing compared to the VEET (p < 0.001) and Clouclip (p = 0.048) and higher intermediate viewing time (p < 0.001). All sensors demonstrated excellent agreement for categorizing outdoor illumination. Activity logs reported significantly greater outdoor durations compared to the VEET, Clouclip, GENEActiv and Actiwatch (p < 0.05 for all). The Actiwatch recorded significantly greater scotopic ( < 3 lux) durations compared to other sensors (p < 0.05 for all). While subjective logs provided useful contextual information, visual activity estimates were significantly different than objective measures. Small but significant discrepancies across sensors emphasize the importance of device selection in myopia research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of wear position on dosimeter performance: measurement validity under simulated indoor illuminationnpj Biological Timing and Sleep · 2026
- Sensor placement causes outcome-dependent bias in ambulatory light-exposure estimatesbioRxiv · 2026
- Cross-validation of wearable light loggers across electric and natural light conditions: focus on illuminance, melanopic EDI, and CCTmedRxiv · 2026
- Impact of wear position on dosimeter performance: a hybrid measurement-simulation approach to quantify in-situ factorsnpj Biological Timing and Sleep · 2026
- Sensing vigilance decrement: a review of physiological measures.Ergonomics · 2026
- Comparing the reliability of sleep metrics across two wrist actigraphs: Philips Actiwatch Spectrum Plus and ActiGraph CentrePoint Insight watchSleep Science and Practice · 2026