Impact of wear position on dosimeter performance: measurement validity under simulated indoor illumination
S. W. de Vries, J. Mardaljevic, J. van Duijnhoven
Eindhoven University of Technology · Loughborough University
Key points
From the paper's conclusion- The results indicate that minimizing the rotational displacement is key to reducing measurement discrepancies and inter-individual variability.
Abstract
The light an individual is exposed to, or personal light exposure (PLE), plays an important role in human health and well-being research. PLE is typically quantified using body-worn light dosimeters (sensors), but their effectiveness as a proxy for measuring at the eye remains insufficiently understood. By combining 3D body scans and lighting simulations, we quantified the discrepancies between chest-worn and eye-level dosimeter measurements under three generalized indoor lighting scenarios. Chest-worn dosimeter performance was found to be highly context-dependent, with the smallest deviations (between -26.2% and 63.8%) observed for devices on the lower chest. Quantifying corneal light exposure, i.e., considering the field of view of the human eye, based on chest-worn dosimeter measurements proved problematic as deviations under overhead lighting exceeded a minimum 25%. To deepen our understanding of the underlying mechanisms, we disaggregated the causes of these discrepancies into three factors: the translational dosimeter displacement, the rotational dosimeter displacement, and body self-occlusion. The results indicate that minimizing the rotational displacement is key to reducing measurement discrepancies and inter-individual variability. To improve the validity of chest-worn dosimetry, an individualized approach is recommended: selecting a chest position where the dosimeter best aligns with the subject's typical view direction during expected activities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of wear position on dosimeter performance: a hybrid measurement-simulation approach to quantify in-situ factorsnpj Biological Timing and Sleep · 2026
- Sensor placement causes outcome-dependent bias in ambulatory light-exposure estimatesbioRxiv · 2026
- Development and Characterization of a Multi-Directional Light Dosimeter for Environmental Light Qualification: The Light Tracker.Sensors (Basel, Switzerland) · 2026
- Cross-validation of wearable light loggers across electric and natural light conditions: focus on illuminance, melanopic EDI, and CCTmedRxiv · 2026
- Five wearable sensors for objective measurement of near work and light exposure.Npj biological timing and sleep · 2026
- Not all light exposure measures are equal: a framework for exposure assessment and causal inference in light epidemiologyBMC Medicine · 2026