Impact of wear position on dosimeter performance: a hybrid measurement-simulation approach to quantify in-situ factors
S. W. de Vries, J. Mardaljevic, J. van Duijnhoven
Eindhoven University of Technology · Loughborough University
Key points
From the paper's conclusion- To overcome limitations of real-world studies, we introduce a novel hybrid measurement-simulation approach to quantify three factors affecting dosimeter performance: the translational and rotational dosimeter displacement and body self occlusion.
Abstract
Quantifications of personal light exposure (PLE) are important for research on human health and well-being. To capture real-world PLE, dosimeters (light sensors) are often worn on the body, rather than at the eye. Currently, it is largely unknown how such placement influences the dosimeter's performance for measuring actual eye-level light exposure. To overcome limitations of real-world studies, we introduce a novel hybrid measurement-simulation approach to quantify three factors affecting dosimeter performance: the translational and rotational dosimeter displacement and body self occlusion. Using 3D body scans of twelve subjects, we illustrate how an individual's body morphology influences the magnitude and distribution of these factors and identify the dosimeter positions where these factors are minimized. Additionally, we defined illustrative limits to identify regions of the chest suitable for dosimeter placement. Depending on the subject's posture, between 0 and 46.4% of the chest area exhibits sufficiently small magnitudes of these factors to be considered suitable. To ensure valid PLE data in light-dosimetry field studies, it is essential to select a dosimeter position that minimizes each of these three factors for typical subject postures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of wear position on dosimeter performance: measurement validity under simulated indoor illuminationnpj Biological Timing and Sleep · 2026
- Sensor placement causes outcome-dependent bias in ambulatory light-exposure estimatesbioRxiv · 2026
- Not all light exposure measures are equal: a framework for exposure assessment and causal inference in light epidemiologyBMC Medicine · 2026
- Development and Characterization of a Multi-Directional Light Dosimeter for Environmental Light Qualification: The Light Tracker.Sensors (Basel, Switzerland) · 2026
- Five wearable sensors for objective measurement of near work and light exposure.Npj biological timing and sleep · 2026
- Cross-validation of wearable light loggers across electric and natural light conditions: focus on illuminance, melanopic EDI, and CCTmedRxiv · 2026