Scientific Reports

Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise

David Camargo, Incinur Zellhuber, Michael Weber, Martin Schönfelder

Key points

From the paper's conclusion
  • The exploratory lactate model demonstrates group-level association ( $$R = 0.84$$ ) and supports the feasibility of thermal-cardiac signal fusion for metabolic monitoring, though individual-level accuracy remains insufficient for clinical use.

Abstract

Continuous monitoring of heart rate (HR) and core temperature ( $$T_c$$ ) is essential for optimizing athletic performance and preventing heat-related illness. However, traditional monitoring methods like chest straps and wrist-worn trackers often face accuracy challenges during exercise due to sweat, motion, and signal interference. Furthermore, few devices offer validated, synchronized HR and $$T_c$$ monitoring during physical exertion. This study validates the MOMENTUM Sport (MSPORT) earbud, a novel multisensor wearable for synchronized HR and $$T_c$$ tracking and investigates its utility in non-invasive blood lactate prediction. Thirty-six healthy adults (19 males, 17 females) performed an incremental cycling ramp test under controlled laboratory conditions. MSPORT HR and $$T_c$$ were validated against Polar H10 and Braun ThermoScan 7 references. Predictive lactate modeling was implemented via a Leave-One-Subject-Out (LOSO) framework, with physiological significance assessed through Linear Mixed Models (LMM) and temporal coupling via cross-correlation analysis. MSPORT showed good inter-device agreement for HR (MAE: 0.89 bpm; RMSE: 1.10 bpm) compared to the Polar H10, and good ear-canal temperature agreement with the Braun ThermoScan 7 (MAE: 0.35 $$^{\circ }$$ C; MAPE: 0.92%). The lactate prediction model achieved a correlation of $$R = 0.84$$ ( $$p < 0.05$$ ), with LMM confirming $$T_c$$ as a highly significant independent predictor ( $$\beta = 11.63$$ , SE = 1.00, $$z = 11.65$$ , $$p < 0.001$$ , 95% CI [9.68, 13.59]), while HR also contributed significantly ( $$\beta = -1.94$$ , SE = 0.29, $$z = -6.78$$ , $$p < 0.001$$ ). The negative HR coefficient likely reflects collinearity or a suppression effect: once cumulative $$\Delta T_c$$ accounts for the metabolic trend, HR becomes a corrective term. Sex was a significant covariate ( $$\beta = -1.25$$ , $$z = -2.00$$ , $$p = 0.046$$ ). The random intercept variance was 1.909, indicating substantial between-participant variability in baseline lactate (model converged; REML). An exploratory cross-correlation analysis suggested a preliminary temporal association between lactate and ear-canal temperature; the precise lag magnitude cannot be reliably estimated from three-minute lactate sampling intervals. Absolute lactate magnitude showed significant sex-based differences ( $$p < 0.05$$ ). The MSPORT earbud provides reliable HR tracking and good ear-canal temperature agreement with a co-located tympanic reference during laboratory cycling. The exploratory lactate model demonstrates group-level association ( $$R = 0.84$$ ) and supports the feasibility of thermal-cardiac signal fusion for metabolic monitoring, though individual-level accuracy remains insufficient for clinical use. Further research is required to assess performance across diverse exercise protocols, environments, and populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers