Short and Long Term Stability of Biochemical Analytes in Cattle Serum Under Varying Storage Conditions.
Almaz Belete Dereje, Yoseph Cherinet Megerssa
College of Veterinary Medicine and Agriculture, Addis Ababa University, Bishoftu, Ethiopia.
Key points
From the paper's conclusion- Storage duration can alter several biochemical analytes even under refrigerated or ultra-low-temperature conditions. Creatinine showed the greatest stability, whereas glucose, total protein, albumin, triglycerides and total cholesterol were more susceptible to storage-related changes. Prompt serum processing and standardized storage procedures are important for reliable biochemical testing in cattle.
Abstract
BACKGROUND: Delays between serum collection and biochemical analysis may alter analyte concentrations and affect the reliability of laboratory results. Evidence on the storage stability of biochemical analytes in cattle serum is limited. This study evaluated the stability of six biochemical analytes under short- and long-term storage conditions. METHODS: Serum samples were obtained from 30 clinically healthy adult male cattle. Samples were analysed at baseline (T0) and after storage at +4°C for 24, 48 and 72 h and at -80°C for 1 and 2 months. Glucose, total protein, albumin, total cholesterol, triglycerides and creatinine were measured using an EMP-168 Biochemical Analyser. Changes over time were evaluated using repeated measures ANOVA with Bonferroni-adjusted post-hoc comparisons. RESULTS: At +4°C, repeated-measures ANOVA showed significant overall time effects for glucose, total protein, albumin and triglycerides, whereas total cholesterol and creatinine showed no significant overall effect. At -80°C, glucose, total protein, albumin, triglycerides and total cholesterol showed significant overall time effects, while creatinine remained stable. Bonferroni-adjusted baseline comparisons showed that glucose did not differ between baseline and 24 h and that triglycerides did not differ between baseline and 1 month during frozen storage. CONCLUSION: Storage duration can alter several biochemical analytes even under refrigerated or ultra-low-temperature conditions. Creatinine showed the greatest stability, whereas glucose, total protein, albumin, triglycerides and total cholesterol were more susceptible to storage-related changes. Prompt serum processing and standardized storage procedures are important for reliable biochemical testing in cattle.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stability of 54 biochemical analytes in capped serum samples stored at 4-8 °C: a 72-h longitudinal evaluation.Clinical chemistry and laboratory medicine · 2026
- Effects of storage temperature and delayed analysis on routine biochemical and haematological test resultsScientific Reports · 2026
- Stability of serum calprotectin as an emerging inflammatory biomarker: a five-day study at -20 °C and -80 °C using two analytical methods.Laboratory medicine · 2026
- Evaluation of a Commercially Available Canine C-Reactive Protein Assay Across Institutions and After 2 Years of Frozen Storage.Veterinary clinical pathology · 2026
- Pre-analytical stability of 7α-hydroxy-4-cholesten-3-one (7aC4): a systematic evaluation under clinically relevant storage conditions.Annals of clinical biochemistry · 2026
- Biological Response Stability of Refrigerated Cosacthen after Opening and Non-Hormonal Effects of ACTH Stimulation Testing in Healthy Dogs.Topics in companion animal medicine · 2026