Research on Fault Diagnosis and Classification of High‐Voltage Transmission Lines Based on an Improved CNN Model
Qiugen Pei, Haiyan Li, Jiaxin Lin, Weicong Ruan, Qiang Yan, Guanshou Chen
Key points
From the paper's conclusion- The results can provide technical support for high‐voltage transmission‐line fault diagnosis under complex operating conditions.
Abstract
To address the limitations of traditional convolutional neural networks (CNNs) in high‐voltage transmission‐line fault diagnosis, where fixed local receptive fields are difficult to represent broadband transient multiscale features and purely data‐driven paradigms lack physical consistency, a physics‐guided Fourier operator convolutional network (PG‐FCNN) is proposed. First, a frequency‐domain convolution module based on a Fourier neural operator is designed to extract multiscale transient features within the effective frequency band using a global receptive field. Second, a physics decoder based on the telegrapher’s equations is incorporated in parallel, with the residual of the distributed‐parameter transmission‐line model used as a physics‐based regularization constraint. A dataset containing 127,450 samples is constructed using real fault‐recording data from 87,500 kV and 220 kV transmission lines in a regional power grid in China from 2015 to 2025. Experimental results show that PG‐FCNN achieves a diagnostic accuracy of 98.82%, with macroaveraged precision, recall, and F1 score of 96.94%, 97.61%, and 97.26%, respectively. In the ablation experiment, the macroaveraged F1 scores of the baseline CNN, CNN + physics, F‐CNN, and PG‐FCNN are approximately 94.3%, 95.7%, 96.5%, and 97.2%, respectively. Compared with F‐CNN, PG‐FCNN further improves macroaveraged precision, recall, and F1 score by approximately 0.8, 0.8, and 0.7 percentage points, respectively. Across five independent runs, the accuracy and macroaveraged F1 score of PG‐FCNN are 98.82% ± 0.02% and 97.26% ± 0.03%, respectively. After removing the physics decoder during inference, the computational cost is only 0.33 GFLOPs. Compared with CNN‐LSTM, ResNet‐18, and transformer, PG‐FCNN achieves the highest accuracy and macroaveraged F1 score and maintains diagnostic accuracies of 93.61%–95.33% under nonideal operating conditions, including noise, CT saturation, high‐resistance grounding, and channel loss. The results can provide technical support for high‐voltage transmission‐line fault diagnosis under complex operating conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approachScientific Reports · 2026
- Physics-Guided Dual-Domain Transformer for Reliable Partial Discharge Recognition of Power Cable Insulation under Heterogeneous Acquisition ConditionsEngineering Research Express · 2026
- A Hybrid Two-Stage Machine Learning Pipeline for Fault Detection and Classification in Power Transmission SystemsarXiv · 2026
- Multi-resolution perceiver-based residual attention for explainable fault diagnosis in power transmission systems.Frontiers in artificial intelligence · 2026
- Fault identification and localization in transmission lines using an IVY-optimized generalized additive modelScientific Reports · 2026
- Multimodal knowledge-guided method for power transmission line fault detection using a vision-language modelInternational Journal of Electrical Power & Energy Systems · 2026