Journal of Physics: Conference Series

CFRP sheet-strengthened post-high-temperature square concrete-encased CFST columns: axial mechanical behavior

Guolin Wei, Shitao Qin, Yu Dan, Jianzeng Shen, Youhua Long

Key points

From the paper's conclusion
  • The results indicate that after 800 °C high-temperature exposure, the cubic compressive strength of concrete suffered a 59.87% loss, and the mechanical properties of steel materials experienced varying degrees of degradation.

Abstract

This study aims to elucidate the strengthening efficacy and mechanical modification mechanism of carbon fiber reinforced polymer (CFRP) sheets on square concrete-encased concrete-filled steel tube (CFST) columns after exposure to high temperature. Taking the steel tube diameter and high-temperature constant duration as the control variables, axial compression tests were carried out on the specimens exposed to 800 °C high temperature after being strengthened with externally bonded single-layer CFRP sheets. The high-temperature damage characteristics of steel and concrete, as well as the failure modes, load-displacement responses, ultimate bearing capacity, initial axial compressive stiffness, and ductility performance of the columns, were systematically analyzed. On this basis, the enhancement effect of CFRP on the mechanical properties of post-high-temperature members and the influence law of key parameters were revealed. The results indicate that after 800 °C high-temperature exposure, the cubic compressive strength of concrete suffered a 59.87% loss, and the mechanical properties of steel materials experienced varying degrees of degradation. Compared with the unstrengthened control specimen, the ultimate bearing capacity, initial axial compression stiffness, and ductility coefficient of single-layer CFRP-strengthened specimens increased by 14.0%, 17.58%, and 4.76%, respectively. The bearing capacity and ductility of the specimens were significantly improved with the increase of steel tube diameter (i.e., steel ratio). The high-temperature constant duration had a limited effect on the bearing capacity, but exerted a remarkable influence on the initial axial compressive stiffness, and the ductility of the members exhibited an upward trend with the extension of constant duration. This research provides a reliable experimental basis and data reference for the strengthening design of concrete-encased CFST columns after fire-induced high temperature.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers