Rotational behaviour and morphological associations of the CT-based distal ulnar centering and eccentricity (DUCE) method in cadaveric specimens
Jan Siad El Barbari, Florian Kordon, Holger Kunze, Jonas Armbruster, Paul Alfred Grützner, Sven Yves Vetter, Marc Schnetzke, Benedict James Swartman
Key points
From the paper's conclusion- The CT-based Distal Ulnar Centering and Eccentricity (DUCE) method describes DRUJ articulation relative to individual notch geometry, separating rotational translation into direction and magnitude.
Abstract
Non-invasive assessment of distal radioulnar joint (DRUJ) stability remains challenging because CT-based measurements, such as the radioulnar ratio (RR), depend on forearm rotation and notch anatomy. The CT-based Distal Ulnar Centering and Eccentricity (DUCE) method describes DRUJ articulation relative to individual notch geometry, separating rotational translation into direction and magnitude. Thirty cadaveric upper limbs underwent cone-beam CT in pronation and supination, 11 also in neutral rotation. Centering (ulnar head centre to a notch-derived reference axis) and Eccentricity (to the deepest notch point) were compared with RR. RR varied with rotation (28.7 ± 8.5% vs. 70.8 ± 13.6%; P < 0.001) and with notch morphology (R 2 up to 0.31); no such association was detected for DUCE. Signed Centering reversed systematically (+ 3.11 vs. − 3.10 mm; P < 0.001), while its magnitude remained equivalent. Averaged across both end positions, Centering was equivalent to zero (exploratory ± 0.6 mm equivalence margin; TOST P < 0.001), placing the notch-derived axis at the centre of the rotational arc at group level, though not in individual limbs. Eccentricity did not differ with rotation. Interrater reliability was good to excellent. DUCE provides an anatomically referenced description of rotational DRUJ behaviour. Clinical studies must show whether it improves assessment of pathological instability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Distal Ulnar Centering and Eccentricity (DUCE) grading: assessing the degree of instability in the distal radioulnar jointScientific Reports · 2026
- Intra- and Interobserver Reliability of the CT-Based Glenoid Arc-Angle Method Using Injured-Side and Contralateral Reference Circles: A Diagnostic Reliability Study.Diagnostics (Basel, Switzerland) · 2026
- Correlation of Radial and Ulnar Shaft Bowing Using the 3D Central Line Method.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Cephalometric Changes Associated with Clockwise and Counterclockwise Mandibular Rotation in Adult Orthodontic Patients, with an Assessment of Reuleaux Center-of-Rotation EstimationApplied Sciences · 2026
- Comparison of computed tomography-based tibial torsion measurement techniques reveals significant technique-dependent differences.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- Corrective Osteotomy With Volar Plating of Distal Radius Malunions Using CT-Based 3D Modeling: A Case Series of Four Patients.Case reports in orthopedics · 2026