Case reports in orthopedics

Corrective Osteotomy With Volar Plating of Distal Radius Malunions Using CT-Based 3D Modeling: A Case Series of Four Patients.

Carl Christian Holkgaard Burvil, Emil Toft Petersen, Janni Kjærgaard Thillemann, Jan Duedal Rölfing, Maiken Stilling

AutoRSA Research Group Orthopaedic Research Unit Aarhus University Hospital Aarhus N Denmark auh.dk. · Department of Clinical Medicine Aarhus University Aarhus Denmark au.dk.

Case report · n=4

Key points

From the paper's conclusion
  • We evaluated the feasibility and outcomes of CT‐based 3D planning for corrective osteotomy in four patients with symptomatic distal radius malunion.

Abstract

Distal radius malunion is the most common complication following distal radius fractures and may lead to reduced forearm rotation, distal radioulnar joint (DRUJ) instability, and wrist pain. Corrective osteotomy is particularly challenging in complex three-dimensional (3D) deformities. We evaluated the feasibility and outcomes of CT-based 3D planning for corrective osteotomy in four patients with symptomatic distal radius malunion. Surgical planning was based on mirrored 3D models of the contralateral healthy radius. Two patients underwent simultaneous foveal triangular fibrocartilage complex (TFCC) reinsertion, while a third underwent delayed TFCC reinsertion combined with ulnar shortening osteotomy. Patients were assessed preoperatively and at 1-year follow-up using CT-based 3D bone models, dynamic radiostereometric analysis (dRSA) of DRUJ kinematics, radiographic parameters, clinical examination, and patient-reported outcome measures (QuickDASH and PRWHE). Anatomical correction improved in all patients, with the greatest improvements observed in rotational alignment. Radiographic parameters improved in all cases, although adequate radial length was restored in only two patients. QuickDASH scores improved in three patients, and PRWHE scores improved in all four. DRUJ kinematics demonstrated improved stability in two patients, no change in one, and worsening in one. Grip strength remained unchanged, while wrist range of motion improved in one patient. CT-based 3D planning was feasible in all cases and facilitated accurate correction of complex distal radius malunions, particularly rotational deformities. Bony realignment improved DRUJ stability with and without TFCC reinsertion but did not restore normal kinematics in all patients. These findings suggest that TFCC stabilization should be reserved for patients with persistent symptomatic DRUJ instability after osteotomy healing and rehabilitation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers