Comparison of computed tomography-based tibial torsion measurement techniques reveals significant technique-dependent differences.
Marcis Benefelds, Ulrich Juen, Peter Kaiser, Richard Lindtner, Moritz Kummann, Raul Mayr
Department of Orthopaedics and Trauma Surgery, Medical University of Innsbruck, Innsbruck, Austria. · Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
Key points
From the paper's conclusion- Conclusion Tibial torsion values depended strongly on the measurement technique used.
Abstract
PURPOSE: To compare commonly used computed tomography (CT)-based tibial torsion measurement discrepancies and evaluate their intra- and interobserver agreement, as measurement discrepancies between techniques have not been systematically assessed. METHODS: CT scans from 20 adult patients were retrospectively analysed. Tibial torsion was calculated using two proximal reference axes (posterior tibial plateau tangent and tibial tuberosity axis) and four distal axes (transmalleolar, ankle joint, Jend and Waidelich). Three observers performed all measurements independently and repeated them after 8-12 weeks. Differences among techniques were assessed using repeated-measures analysis of variance with Bonferroni correction. Reliability was evaluated using intraclass correlation coefficients (ICCs). RESULTS: All measurement techniques differed significantly (p < 0.05). Mean tibial torsion was 34.1° (standard deviation [SD] 8.6°) for the transmalleolar axis, 31.2° (SD 8.8°) for the ankle joint axis, 44.2° (SD 9.8°) for the Jend axis and 34.9° (SD 9.0°) for the Waidelich axis. Segmental values revealed a mean supratuberositary torsion of 26° (SD 6.7°) and a mean infratuberositary torsion of 7.9° (SD 8.8°) for the transmalleolar axis, 5.1° (SD 8.9°) for the ankle joint axis, 18.1° (SD 10.4°) for the Jend axis and 8.8° (SD 9.1°) for the Waidelich axis. All techniques showed excellent intra- and interobserver reliability (ICC > 0.89). CONCLUSION: Tibial torsion values depended strongly on the measurement technique used. Technique-specific normative values are essential, and radiology reports should explicitly identify the technique applied. Clinicians must account for these systematic differences when interpreting torsion values and planning derotational osteotomies. LEVEL OF EVIDENCE: Level III, retrospective comparative study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FP15.3 Computed Tomography–Based Tibial Torsion Measurements Are Method-Dependent and Alter the Classification of Excessive External Tibial TorsionFP15.3Journal of Hip Preservation Surgery · 2026
- Posterior tibial slope measurements remain accurate only within ±5° of tibial rotation: A cadaveric computed tomography-radiograph study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- TP3.3 Lateral Center-Edge Angle Measurements on Computed Tomography Are Higher Compared To Measurements On Plain Radiograph But Alpha Angle and Tönnis Angle Are Similar: A Systematic Review and Meta-AnalysisJournal of Hip Preservation Surgery · 2026
- A Novel Radiographic Classification of the Proximal Tibiofibular Joint.Medicina (Kaunas, Lithuania) · 2026
- Standing Long-Leg Radiographs Underestimate Varus Alignment and Joint Line Obliquity Compared With Computed Tomography in Japanese Patients.Cureus · 2026
- Quantitative Whole-Leg Radiographic Assessment of Coronal Knee-Ankle Alignment: Associations with Talar Inclination and Exploratory Changes After Knee Osteotomy.Diagnostics (Basel, Switzerland) · 2026