Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Mohamed A. Ghalib, M. S. Elbrolsy, R. Mostafa, H.E. Keshta
Beni-Suef University · Benha University
Key points
From the paper's conclusion- The results demonstrate the superior performance of the MRAC-FPI-WOA controller across diverse operational scenarios.
Abstract
The concept of Islanded Hybrid Power System (IHPS) has attracted considerable interest lately, especially for energizing remote or energy-poor locations. IHPS are more dependable and cost-effective alternatives to systems using only one energy source when properly constructed. IHPS configuration, including Diesel Engine Generator (DEG), Photovoltaic (PV) systems, and Battery Storage (BATT) elements, are desirable for islanded systems about price and dependability. IHPS mostly use Renewable Energy Sources (RES) for power production, which is variable. Consequently, these variations often make it difficult for traditional control systems to maximize efficiency across various operating environments. The current research discusses the requirement for more effective frequency control in IHPS by suggesting a Model Reference Adaptive Control-Fuzzy Proportional Integral based Whale Optimization Algorithm (MRAC-FPI-WOA) controller. The proposed controller can efficiently manage a range of disturbances by dynamically adjusting its control techniques. The current research conducts an evaluation study comparing the effectiveness of the suggested MRAC-FPI-WOA controller against FPI-WOA, PI-WOA, and PI-PSO controllers. The key evaluation criteria are the ability to maintain stability in frequency within the IHPS and the effectiveness of power production in the overall system. The results demonstrate the superior performance of the MRAC-FPI-WOA controller across diverse operational scenarios. Notably, during a three-phase fault at Bus2, the MRAC-FPI-WOA controller achieves significant performance enhancements over the PI-PSO controller, with reductions of 59.05% in maximum overshoot (%), 72.83% in maximum undershoot (%), 32.07% in settling time , and 34.81% in the integral of time-weighted absolute error (ITAE). A similar trend is observed during a three-phase fault at the tie-line, where the MRAC-FPI-WOA controller yields improvements of 57.47% in %, 79.36% in %, 40.9% in, and 78.08% in ITAE. Furthermore, the controller exhibits exceptional dynamic responsiveness to ramp variations in solar radiation, substantially reducing % by 96.72%, % by 95.24%, by 22.79%, and ITAE by 89.69%. Additionally, it demonstrates robust adaptability to random solar radiation fluctuations, consistently optimizing transient response with reductions of 96.63% in %, 99.58% in %, 22.07% in, and 95.23% in ITAE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fuzzy PI Controller for Frequency Control of A Diesel-PV-Battery-Based Islanded AC MicrogridMEJ Mansoura Engineering Journal · 2026
- Adaptive Energy Management and Control of an Autonomous PV-Wind-Diesel-BESS Hybrid Microgrid: A Case Study on Tioman Island, MalaysiaResults in Engineering · 2025
- Intelligent and resilient techniques for dynamic behavior optimization in renewable energy systemsEnergy Reports · 2025
- Intelligent frequency regulation in islanded microgrids using a crayfish-tuned FO–(PD–PI) controller with energy storage coordinationJournal of low frequency noise, vibration and active control · 2026
- Novel intelligent model following controller and PQ droop controller operated nuclear-PV-biogas hybrid microgrid and EV charging stationComputers & Electrical Engineering · 2025
- Enhanced power management in PV-Integrated hybrid energy storage systems using fuzzy 2DOF-PI control optimized by hippopotamus algorithmScientific Reports · 2026