Microsystems & nanoengineeringOpen accessPhotothermal therapy

Development and application of a smartphone-based thermal contrast amplification reader for photothermal lateral flow immunoassays.

Jiajie Liang, Peijun Teng, Lei Wu, Wanli Liang, Qifang Song, Guanbo He, Yanqiang Hao, Haorong He,

Research Center of Cancer Diagnosis and Therapy, Department of Oncology, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, PR China. 631101522@qq.com. · GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, 510632, PR China.

Observational

Key points

From the paper's conclusion
  • To address this, we developed a smartphone-based handheld Thermal Contrast Amplification (TCA) Reader, eliminating the need for costly external hardware.

Abstract

The high cost and poor portability of external infrared thermal imagers have limited the widespread adoption of photothermal lateral flow immunoassays (PT-LFIAs) in on-site testing. To address this, we developed a smartphone-based handheld Thermal Contrast Amplification (TCA) Reader, eliminating the need for costly external hardware. Compared with existing recent external thermal imager-based PT-LFIA readout, this reader integrates a selected thermal-sensor-equipped smartphone, a motorized laser module, Bluetooth-enabled control, and a fixed 3D-printed holder into a compact device. The reader enables automated thermal signal acquisition with a same-strip measurement CV below 1% and supports multiple PT-LFIA formats. Using Au@Ag core-shell nanoparticles (Au@Ag NPs) as reliable photothermal labels, the handheld TCA reader-based PT-LFIAs (hT-PT-LFIAs) offers higher sensitivity compared to conventional LFIAs. The hT-PT-LFIAs can be used for the multiplex detection of viral antigens (Influenza A/B, SARS-CoV-2), small molecule drugs (morphine, methamphetamine, ketamine) and nucleic acids (HPV 16/18), demonstrating versatility across various LFIA formats, good clinical performance in training cohort, and high repeatability for small molecule assay. By seamlessly integrating micro-engineering, nanotechnology, and smartphone-based sensing, this work provides a low-cost, portable, and broadly applicable PT-LFIAs detection strategy that bridges a critical technological gap.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development and application of a smartphone-based thermal contrast amplification reader for photothermal lateral flow immunoassays — Science Skim