Analytical methods : advancing methods and applications

Multimodal LFIA platform integrating visual readout, smartphone grayscale imaging and surface-enhanced Raman scattering for point-of-care detection of SARS-CoV-2 protein.

Qingling Tang, Zhangying Jiang, Duo Lin

Key Laboratory of Optoelectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350117, China. duo@fjnu.edu.cn. · Fuzhou Hospital of Traditional Chinese Medicine, Fuzhou, 350001, China.

Key points

From the paper's conclusion
  • These results demonstrate that the proposed multimodal LFIA strategy preserves the simplicity of conventional strips while enabling digital interpretation and sensitive low-concentration antigen detection in saliva-like matrices.

Abstract

Rapid, simple, and sensitive antigen detection remains important for point-of-care screening and respiratory infection surveillance. Conventional lateral flow immunoassays (LFIAs) enable rapid visual testing, but their sensitivity is often limited for low-abundance viral antigens. Herein, we developed a multimodal LFIA platform for SARS-CoV-2 nucleocapsid (N) protein detection in simulated saliva. The platform integrates three complementary readout modes on a single strip: naked-eye visual observation for rapid qualitative screening, smartphone grayscale imaging for digital recording and semi-quantitative comparison of test-line color intensity, and surface-enhanced Raman scattering (SERS) measurement for sensitive spectral quantification. Citrate-capped gold nanoparticles were labeled with 4-mercaptobenzoic acid and conjugated with anti-SARS-CoV-2 N protein detection antibodies to construct Raman-active immunoprobes. The calculated analytical limit of detection (LOD) was 5.2 pg mL-1, whereas 50 pg mL-1 was the lowest experimentally tested concentration that produced a clearly distinguishable SERS response. The lowest experimentally distinguishable concentration for smartphone grayscale analysis was 160 pg mL-1. The naked-eye visual threshold was approximately 200 pg mL-1. In simulated saliva samples, recoveries ranged from 87.70% to 103.70%, with relative standard deviations of 4.8-7.1%. These results demonstrate that the proposed multimodal LFIA strategy preserves the simplicity of conventional strips while enabling digital interpretation and sensitive low-concentration antigen detection in saliva-like matrices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Multimodal LFIA platform integrating visual readout, smartphone grayscale imaging and surface-enhanced Raman scattering for point-of-care detection of SARS-CoV-2 protein — Science Skim