Streptavidin-Biotin Binding Is Intrinsically Noncooperative, but Experimental Artifacts Can Induce Apparent Positive Cooperativity.
Malavika Kayyil Veedu, Eléonore Martenne Duplan, Saurabh Rai, Prithu Roy, Jérôme Wenger
Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, AMUTech , 13013Marseille, France.
Key points
From the paper's conclusion- By establishing the noncooperative nature of biotin–streptavidin binding and identifying the key conditions to avoid cooperativity artifacts, these insights resolve a longstanding debate and offer critical implications for streptavidin-based biotechnological applications.
Abstract
The biotin-streptavidin interaction is a key component of nanobiotechnology, yet the nature of its cooperativity remains a debated question. Here, we introduce a label-free spectroscopy approach based on confocal UV autofluorescence microscopy to probe the binding cooperativity of this high-affinity system. By leveraging the intrinsic autofluorescence of tryptophan residues, we avoid artifacts associated with extrinsic fluorescent labels, enabling precise measurements of fully biotin-saturated streptavidin across a wide range of molar ratios. Our experimental results, supported by Monte Carlo simulations, provide conclusive evidence for the absence of cooperativity. However, we show that false signs of apparent positive cooperativity can emerge from local concentration inhomogeneities occurring when rapid reaction kinetics outpace mixing. By establishing the noncooperative nature of biotin-streptavidin binding and identifying the key conditions to avoid cooperativity artifacts, these insights resolve a longstanding debate and offer critical implications for streptavidin-based biotechnological applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays.Analytical chemistry · 2026
- Signal Nonadditivity and Model Mismatch in Microscale Thermophoresis Can Severely Bias Kd Determination.ACS sensors · 2026
- Extending conventional TIRF microscopy to image single molecules in micromolar analyte backgroundsbioRxiv · 2026
- A series of spontaneously blinking dyes for super-resolution microscopyNature Methods · 2026
- Photophysical effects in long-lifetime fluorophore-protein conjugates and their influence on fluorescence polarization immunoassays.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Charge Detection Native Mass Spectrometry for Quantitative Insights into Heterogeneous Protein Interactions.Analytical chemistry · 2026