Trap-and-Lock Nano-Trap of Molecularly Imprinted Dendritic Mesoporous Core@Thermoresponsive Shield Enables Efficient Depletion of Free Biotin for Accurate Immunoassays.
Bao-Xuan Xie, Xiawen Lin, Song Gao, Jian He, Zhen Liu
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry, Nanjing University, 163 Xianlin Avenue, Nanjing210023, P. R. China. · The Affiliated Drum Tower Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing210008, P. R. China.
Key points
From the paper's conclusion- Thus, this work provides an appealing approach with high translational potential for addressing biotin interference in immunoassays.
Abstract
The streptavidin-biotin system underpins numerous immunoassays for immobilization, labeling, and signal amplification, yet it is highly susceptible to interference from free biotin in biosamples, leading to inaccurate results and potential clinical misdiagnosis. Current countermeasures remain unsatisfactory, as antibody- or streptavidin-based scavenging strategies suffer from limited depletion capacity, poor assay compatibility, or separation-dependent workflows, making them difficult to broadly integrate into automated immunoassays. Herein, we present a rationally engineered nano-trap that ingeniously integrates a biotin-imprinted dendritic mesoporous core with a thermoresponsive shield, enabling efficient elimination of free biotin interference through a "trap-and-lock" strategy. At room temperature, the nano-trap remains in an "open" state, restricting proteins entry while allowing efficient and high-capacity trapping of free biotin, whereas at immunoassay temperature, it switches to a "close" state, firmly locking the captured biotin and preventing its rebinding to streptavidin. The thermoresponsive shield is grafted with phosphorylcholine to suppress protein adsorption, further making the nano-trap highly compatible with complex biosamples. Simply adding a trapping step prior to protein assays on a mainstream immunoassay workstation achieves an outstanding tolerance to free biotin up to 1000 ng/mL. This tolerance not only exceeds the reported biotin tolerance of many commercial immunoassays, including assays optimized for biotin interference, but also substantially covers the serum biotin levels associated with high-dose biotin therapy. The nano-trap is widely applicable to protein assays and compatible with commercial kits and instruments. Thus, this work provides an appealing approach with high translational potential for addressing biotin interference in immunoassays.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermodynamic Microenvironment Engineering in Mesoporous Nanoreactors to Enhance Biocatalysis for AI-Empowered Ultrasensitive Pathogen DetectionAnalytical Chemistry · 2025
- Molecular Programming of Steric Tags for Controlled Nanopore Translocation toward Precision Clinical Diagnostic Assistance.Journal of the American Chemical Society · 2026
- A bioorthogonal capture-and-release platform for isolation of nanoparticle protein coronas.Journal of materials chemistry. B · 2026
- Spatially multiplexed microneedle biosensors for low-abundance protein biomarker monitoring in dermal interstitial fluid.Science advances · 2026
- Lactate-Depleting Nanotherapy Reprograms the Immunometabolic Microenvironment to Overcome Biofilm Tolerance in Implant-Associated Infections.Advanced materials (Deerfield Beach, Fla.) · 2026
- Tuberculosis biomarker detection using the intrinsic photoluminescence of carbonated hydroxyapatite nanoparticles.Talanta · 2026