Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Photophysical effects in long-lifetime fluorophore-protein conjugates and their influence on fluorescence polarization immunoassays.

E V Sanin, A L Tatarets, S U Khabuseva, T Yu Gromovoy, E Terpetschnig

Institute of Macromolecular Chemistry CAS Heyrovského nám. 1888/2, 162 00 Prague 6, Czech Republic. Electronic address: saninedward@gmail.com. · State Scientific Institution "Institute for Single Crystals" of National Academy of Sciences of Ukraine, 60 Nauky Ave., Kharkiv 61072, Ukraine.

Key points

From the paper's conclusion
  • We report a spectroscopic investigation of SeTau-405- and SeTau-425-lysozyme conjugates and evaluate how their photophysical properties influence fluorescence polarization immunoassays.

Abstract

We report a spectroscopic investigation of SeTau-405- and SeTau-425-lysozyme conjugates and evaluate how their photophysical properties influence fluorescence polarization immunoassays. The conjugates were characterized by absorption and fluorescence spectroscopy, fluorescence lifetime and polarization measurements, and MALDI-TOF mass spectrometry. Their fluorescence polarization values were lower than those predicted by a simplified rotational-diffusion model. For SeTau-405-lysozyme, the pronounced decrease in quantum yield with increasing dye-to-protein ratio (D/P), together with small lifetime changes, is consistent with a contribution from static quenching. Strongly quenched species contribute little to the detected fluorescence, which may therefore predominantly reflect sparsely labeled molecules and other emissive conjugate species. Antibody binding increased polarization, while the polarization reached at saturation depended more strongly on D/P than that of the free conjugates. This behavior is discussed in terms of restricted global rotation, local fluorophore mobility, dye-protein interactions, and possible homo-FRET, including between labeled antigens brought into proximity by bivalent antibody binding. MALDI-TOF confirmed covalent conjugation and revealed higher-mass species under the measurement conditions. The conjugates were applied in a model immunoassay for lysozyme over the concentration range of 0.10-0.75 μM (1.4-10.5 μg/mL), with estimated detection limits of 20 nM and 60 nM for the SeTau-405 and SeTau-425 systems, respectively. These findings highlight the combined influence of labeling density, quenching, and antibody binding on fluorescence polarization assay performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers