Enzyme-Induced Photocurrent Polarity Reversal in a Zr-MOF/COF Photoelectrochemical Immunosensor for Ultrasensitive Detection of Cancer Markers.
Seyede Somayeh Hosseini, Samira Mansouri Majd, Abdollah Salimi, Keivan Akhtari
Department of Chemistry, University of Kurdistan, Sanandaj66177-15175, Iran. · Department of Semiconductors, Materials and Energy Research Center (MERC), P.O. Box 31787-316, Karaj, Iran.
Key points
From the paper's conclusion- This study demonstrates the potential of photocurrent polarity switching as a reliable and sensitive strategy for PEC biosensing and biomolecular detection.
Abstract
Photocurrent polarity switching provides an effective strategy for improving the reliability and sensitivity of photoelectrochemical (PEC) biosensors by reducing false-positive responses. Herein, we developed a polarity-switchable PEC immunosensor for ultrasensitive detection of prostate-specific antigen (PSA) based on an in situ electron donor generation strategy using a Zr-based metal-organic framework (Zr-MOF)/thionine-cyanuric chloride covalent organic framework (Th-CC-COF) heterojunction. The modified electrode, prepared using an optimized 1:1 mass ratio of Zr-MOF to Th-CC-COF, initially exhibited a cathodic photocurrent. PSA recognition in the conventional immunosensing mode decreased the photocurrent, enabling PSA detection over a linear range from 0.10 pg/mL to 1.0 ng/mL with a detection limit of 0.023 pg/mL. To enhance the analytical performance, a sandwich immunoassay with an alkaline phosphatase-labeled secondary antibody was constructed. The enzymatic hydrolysis of ascorbic acid 2-phosphate generated ascorbic acid (AA) in situ, which acted as an electron donor and switched the photocurrent from cathodic to anodic. The resulting polarity-switchable signal-on strategy provided a wider linear range from 0.010 pg/mL to 1.0 ng/mL and a lower detection limit of 3.5 fg/mL, together with improved sensitivity compared with the cathodic sensing mode. The proposed immunosensor also showed satisfactory resistance to the tested interfering proteins, and its applicability was demonstrated by the analysis of spiked human serum samples, with results comparable to those obtained by enzyme-linked immunosorbent assay (ELISA). This study demonstrates the potential of photocurrent polarity switching as a reliable and sensitive strategy for PEC biosensing and biomolecular detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers.Biosensors & bioelectronics · 2026
- An anti-fouling photoelectrochemical-electrochemical sensing platform with a zwitterionic interface and a photocurrent-polarity-switching strategy.Biosensors & bioelectronics · 2026
- In Situ Ion-Exchange-Mediated Dynamic Nanointerface Reconfiguration for Polarity-Switchable Photoelectrochemical-Photothermal Biosensing.Journal of the American Chemical Society · 2026
- Photoelectrochemical and colorimetric dual-mode aptasensor for nonylphenol detection in food based on ascorbic acid-sensitive Bi2S3/Bi2O2CO3 heterojunction and multi-enzyme-mimicking Ce-MOF.Food chemistry · 2026
- Core-Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay.Analytical chemistry · 2026
- Dual-Polarity Switching Photoelectrochemical Biosensor Based on Z-Scheme Bi2S3/Bi2WO6 Heterojunction for Clinical Thalassemia Screening: Cascade Signal Amplification via 3D DNA Walker and Target Recycling.Analytical chemistry · 2025