Core-Shell ZIF-67@CoFePBA Nanozyme with Dual Functions in PEC Signal Modulation and Fenton-like Colorimetric Catalysis for Cyfra21-1 Immunoassay.
Xiaopan Cui, Yinpeng Jiang, Dawei Fan, Yu Du, Huan Wang, Yuyang Li, Qin Wei, Dan Wu
School of Chemistry and Chemical Engineering, University of Jinan, Jinan250022, P. R. China. · School of Water Conservancy and Environment, University of Jinan, Jinan250022, P. R. China.
Key points
From the paper's conclusion- Meanwhile, under the colorimetric detection mode, the ZIF-67@CoFePBA nanozymes catalyzed the 3,3′,5,5′-tetramethylbenzidine (TMB)/H2O2 reaction to generate a visually distinguishable colorimetric signal.
Abstract
A novel dual-mode immunosensing platform integrating photoelectrochemical (PEC) and colorimetric detection was developed for the early and reliable determination of the non-small cell lung cancer biomarker cytokeratin 19 fragment (Cyfra21-1). An ordered ReS2/In2S3 type-II heterojunction array was constructed, which not only enlarged the effective electroactive surface area but also introduced an interfacial built-in electric field. As a result, the separation and directional transport of photogenerated charge carriers were significantly promoted, leading to markedly enhanced photoelectric conversion efficiency. In addition, ZIF-67@CoFePBA nanozymes with peroxidase-like activity were employed as dual-function signal probes. Under the PEC detection mode, the photocurrent signal was significantly suppressed during the immunorecognition process, as the steric hindrance effect induced by ZIF-67@CoFePBA nanozymes inhibited the effective migration of photogenerated charge carriers, thereby enabling the quantitative determination of Cyfra21-1. Good linear analytical performance was achieved over a concentration range from 100 fg/mL to 50 ng/mL, with a detection limit of 66.5 fg/mL. Meanwhile, under the colorimetric detection mode, the ZIF-67@CoFePBA nanozymes catalyzed the 3,3',5,5'-tetramethylbenzidine (TMB)/H2O2 reaction to generate a visually distinguishable colorimetric signal. A good linear response was obtained in the concentration range of 0.5-25 ng/mL, with a detection limit of 0.14 ng/mL. The dual-signal output endowed the platform with an intrinsic self-validation capability through cross-verification of two independent yet correlated signal channels, thereby effectively minimizing false responses induced by environmental interference. This provides a promising analytical strategy for lung cancer biomarker detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enzyme-Induced Photocurrent Polarity Reversal in a Zr-MOF/COF Photoelectrochemical Immunosensor for Ultrasensitive Detection of Cancer Markers.Langmuir : the ACS journal of surfaces and colloids · 2026
- Synergistic Signal Amplification by Cu₂ O‐Au/Ag Nanozyme in Heterojunction Photoanode for High‐Sensitivity Photoelectrochemical Detection of Cyfra21‐1Small · 2025
- Synergistic PEC-FL microfluidic biosensing based on liposome-regulated Co-CQDs and Z-scheme BiVO4/Au/ZnIn2S4 for sensitive detection of CA19-9.Biosensors & bioelectronics · 2026
- Heterovalent Co Doping Boosts the Phosphatase-like Activity of UiO-66-NH₂ for Ultrasensitive Fluorescence Immunoassay of CEAAnalytical Chemistry · 2025
- Target-Induced Tandem Built-In Electric Fields in the Hollow SnS₂ /ZIS@ZnS Heterojunction for the Photoelectrochemical ImmunoassayAnalytical Chemistry · 2026
- A Bifunctional CoFcMOF Nanozyme Enables Dual-Mode PEC-Colorimetric Immunosensing of C-Reactive Protein with Built-In Cross-Validation.ACS sensors · 2026