An anti-fouling photoelectrochemical-electrochemical sensing platform with a zwitterionic interface and a photocurrent-polarity-switching strategy.
Hejie Zheng, Deqi Wang, Beibei Wang, Yubing Lv, Shanghua Liu, Maotian Xu, Yanli Zhou, Xiaoqiang Liu,
Henan Key Laboratory of Biomarker Detection and Diagnosis for Neurodegenerative Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, PR China. · Henan Key Laboratory of Biomarker Detection and Diagnosis for Neurodegenerative Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, PR China. Electronic address: zhouyanli@sqnu.edu.cn.
Key points
From the paper's conclusion- This PSBMA-PDA interface-based anti-fouling thus acts as a dual-mode sensing platform that not only offers good anti-fouling capability by reducing non-specific adsorption, but also sensitively detects PSA over a 10 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 5.0 fg mL-1 PSA in the PEC mode, and a 50 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 24.6 fg mL-1 in the EC
Abstract
In this work, we have developed a photoelectrochemical-electrochemical (PEC-EC) dual-mode sensing platform consisting of a polydopamine (PDA)-poly(sulfobetaine methacrylate) (PSBMA) anti-fouling zwitterionic interface equipped with a photocurrent-polarity-switching strategy. The PSBMA-PDA copolymer anti-fouling layer was attached to a hydrogen bonded organic framework-101 (HOF-101)-Sb2S3 modified indium titanium oxide (ITO) electrode surface using a dopamine mediated coupling reaction. The attachment of the aptamer of the model analyte prostate specific antigen (PSA) was designed to trigger a hybridisation chain reaction that linked the bifunctional factor of thionine-modified hairpin H1 and hairpin H2 to the anti-fouling electrode surface. Thionine then induced a switch from a cathodic to an anodic photocurrent at the PSBMA-PDA-HOF-101-Sb2S3/ITO, while generating a large differential pulse voltammetric current. This PSBMA-PDA interface-based anti-fouling thus acts as a dual-mode sensing platform that not only offers good anti-fouling capability by reducing non-specific adsorption, but also sensitively detects PSA over a 10 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 5.0 fg mL-1 PSA in the PEC mode, and a 50 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 24.6 fg mL-1 in the EC mode. This anti-fouling PEC-EC dual-mode sensing platform is readily applicable to the highly sensitive and selective detection of various disease biomarkers by simply attaching the corresponding DNA aptamer, thereby offering a promising pathway for early clinical diagnosis and point-of-care testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enzyme-Induced Photocurrent Polarity Reversal in a Zr-MOF/COF Photoelectrochemical Immunosensor for Ultrasensitive Detection of Cancer Markers.Langmuir : the ACS journal of surfaces and colloids · 2026
- Self-Powered Anti-Interference Photoelectrochemical Immunosensor Enabled by a Ferroelectric Hybrid Coupled with a Platinum-Doped Peptide HydrogelAnalytical Chemistry · 2026
- Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers.Biosensors & bioelectronics · 2026
- Sulfonated cobalt phthalocyanine coupled with poly(dopamine-co-sulfobetaine methacrylate) for single-cell electrochemical monitoring of glutathione.Biosensors & bioelectronics · 2026
- Self-Assembled Peptide Hydrogel-Engineered Au/SCN/PCN-222 Photocathode for Antifouling Photoelectrochemical Immunoassay of S100B.Analytical chemistry · 2026
- A self-powered photoelectrochemical sensor with ultra-low background based on ZnIn2S4@CdS photoanode and Bi2WO6 photocathode for BACE1 detection.Biosensors & bioelectronics · 2026