Biosensors & bioelectronics

An anti-fouling photoelectrochemical-electrochemical sensing platform with a zwitterionic interface and a photocurrent-polarity-switching strategy.

Hejie Zheng, Deqi Wang, Beibei Wang, Yubing Lv, Shanghua Liu, Maotian Xu, Yanli Zhou, Xiaoqiang Liu,

Henan Key Laboratory of Biomarker Detection and Diagnosis for Neurodegenerative Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, PR China. · Henan Key Laboratory of Biomarker Detection and Diagnosis for Neurodegenerative Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, PR China. Electronic address: zhouyanli@sqnu.edu.cn.

Key points

From the paper's conclusion
  • This PSBMA-PDA interface-based anti-fouling thus acts as a dual-mode sensing platform that not only offers good anti-fouling capability by reducing non-specific adsorption, but also sensitively detects PSA over a 10 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 5.0 fg mL-1 PSA in the PEC mode, and a 50 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 24.6 fg mL-1 in the EC

Abstract

In this work, we have developed a photoelectrochemical-electrochemical (PEC-EC) dual-mode sensing platform consisting of a polydopamine (PDA)-poly(sulfobetaine methacrylate) (PSBMA) anti-fouling zwitterionic interface equipped with a photocurrent-polarity-switching strategy. The PSBMA-PDA copolymer anti-fouling layer was attached to a hydrogen bonded organic framework-101 (HOF-101)-Sb2S3 modified indium titanium oxide (ITO) electrode surface using a dopamine mediated coupling reaction. The attachment of the aptamer of the model analyte prostate specific antigen (PSA) was designed to trigger a hybridisation chain reaction that linked the bifunctional factor of thionine-modified hairpin H1 and hairpin H2 to the anti-fouling electrode surface. Thionine then induced a switch from a cathodic to an anodic photocurrent at the PSBMA-PDA-HOF-101-Sb2S3/ITO, while generating a large differential pulse voltammetric current. This PSBMA-PDA interface-based anti-fouling thus acts as a dual-mode sensing platform that not only offers good anti-fouling capability by reducing non-specific adsorption, but also sensitively detects PSA over a 10 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 5.0 fg mL-1 PSA in the PEC mode, and a 50 fg mL-1 - 100 ng mL-1 linear range and a detection limit of 24.6 fg mL-1 in the EC mode. This anti-fouling PEC-EC dual-mode sensing platform is readily applicable to the highly sensitive and selective detection of various disease biomarkers by simply attaching the corresponding DNA aptamer, thereby offering a promising pathway for early clinical diagnosis and point-of-care testing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers