Dual-Trap Sequential Enrichment System with Photochemical Ionization TOFMS for Automated Simultaneous Determination of DMS and Isoprene in Seawater and Atmosphere.
Qingyi Zheng, Haijie Wang, Yingzhe Guo, Ruidong Liu, Jing Li, Jichuang Kong, Dong Yang, Shibo Yan,
Environment Research Institute, Shandong University, Qingdao266237, China. · Key Laboratory of Global Change and Marine-Atmospheric Chemistry, Third Institute of Oceanography, Ministry of Natural Resources, Siming District, Xiamen, Fujian361005, China.
Key points
From the paper's conclusion- To address these issues, we developed a dual-trap sequential enrichment (DTSE) system with a highly sensitive photochemical ionization TOFMS (PCI-TOFMS).
Abstract
For the detection of dimethyl sulfide (DMS) and isoprene in marine environments, existing methods suffer from limitations in sensitivity, temporal resolution, or the ability to analyze gas-liquid biphasic phases. To address these issues, we developed a dual-trap sequential enrichment (DTSE) system with a highly sensitive photochemical ionization TOFMS (PCI-TOFMS). The DTSE is based on dynamic headspace extraction and dual-trap enrichment, enabling simultaneous efficient extraction and alternating automatic analysis of seawater and air samples. A series of innovative functional designs are embedded into this system, such as in-cycle self-cleaning, stepwise gradient desorption, and dynamic dilution calibration. PCI generates O2+ reagent ions through photoelectrons, and O2+ subsequently ionizes DMS and isoprene via chemical ionization to M+ and [M-H]+, which are subsequently separated and detected with TOFMS. After optimization, the DTSE-PCI-TOFMS system enables continuous extraction and enrichment of seawater and air in a single 5 min analytical cycle, achieving recoveries of 88-90%, enrichment factors of 19-45, and detection limits as low as sub-pM and sub-ppt (S/N = 3), along with good stability (RSD = 1.2-4.2%) and linearity (R2 > 0.99). Compared to conventional P&T-GC-MS methods, the temporal resolution for DMS was reduced from 20 to 5 min, while the detection sensitivity was enhanced by a factor of 17-44. Finally, the practical performance of the DTSE-PCI-TOFMS system was validated by continuously monitoring DMS and isoprene metabolism in the model diatom over 48 h under varying temperature, light, and pH conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermal desorption gas chromatography electron ionization mass spectrometry/proton transfer reaction mass spectrometry (TD-GC-EI-MS/PTR-MS) for broad volatile profiling and multi-reagent spectral library expansion.Journal of chromatography. A · 2026
- Comparison of Two Passive Samplers for Hydrophilic and Lipophilic Phycotoxins and Expansion of Analytical Methods for Quantification Using UPLC-MS/MS.Toxins · 2026
- Performance comparison of UniSprayTM and electrospray ionisation coupled to ion-mobility high-resolution mass spectrometer for screening of organic pollutants in water matrices.Journal of chromatography. A · 2026
- The Development of a Simple Liquid Chromatography‐Precursor Ion Scan‐Mass Spectrometry Screening Method for the Detection of Phytocannabinoids in Plant ExtractsJournal of Mass Spectrometry · 2026
- Online Dual-Ionization Mass Spectrometer Coupling Photoionization and Paper Spray Ionization for Enhanced Detection of Particle Ozonolysis KineticsAnalytical Chemistry · 2026
- An automated flow-injection thin-layer electrochemical platform for online silicate monitoring in marine environments.Talanta · 2026