Journal of chromatography. A

Thermal desorption gas chromatography electron ionization mass spectrometry/proton transfer reaction mass spectrometry (TD-GC-EI-MS/PTR-MS) for broad volatile profiling and multi-reagent spectral library expansion.

Anne E Jung, Alena R Veigl, James A Remley, Rhonda L Pitsch, Sean W Harshman

AV, Inc., 711th Human Performance Wing, Air Force Research Lab, 2510 Fifth Street, Building 840, Area B, Wright-Patterson AFB, OH, USA. · 711th Human Performance Wing, Air Force Research Lab, 2510 Fifth Street, Building 840, Area B, Wright-Patterson FB, OH, USA.

Key points

From the paper's conclusion
  • Overall, the fragmentation library facilitates enhanced compound identification and quantification in real-time PTR-MS spectra, while the TD-GC-EI-MS/PTR-MS platform provides a novel, robust, dual-detection platform for characterizing complex volatile mixtures.

Abstract

Proton Transfer Reaction Mass Spectrometry (PTR-MS) is highly valued for its exceptional sensitivity and real-time volatile organic compound (VOC) monitoring. However, while high-resolution PTR-MS instruments can resolve many isobaric compounds, these instruments struggle with structural isomer differentiation in addition to the detection of low-proton-affinity chemical classes. To address these limitations, a novel approach integrating thermal desorption and gas chromatography with dual detection via electron impact and proton transfer reaction mass spectrometry (TD-GC-EI-MS/PTR-MS) is evaluated using both hydronium (H3O+) and oxygen (O2+) ionization modes. Utility of the TD-GC-EI-MS/PTR-MS setup was illustrated by analyzing a diverse suite of 117 standard compounds across multiple chemical families including alcohols, aldehydes, ketones, alkanes, alkenes, aromatics, short-chain fatty acids, etc. Data were collected using both ionization modes, H3O+ and O2+, within the PTR-MS under a uniform reduced electric field strength (121 townsend (Td)). The results demonstrate the TD-GC-EI-MS/PTR-MS system provides consistent low background, low carryover data with an approximate 2.08min retention time delay between the EI detection and PTR detection. The data highlight the ability of a novel TD-GC-EI-MS/PTR-MS system to analyze complex volatile mixtures through simultaneous EI-MS and PTR-MS detection. The results show data, curated into a library, supporting the fragmentation patterns of 28 previously uncharacterized compounds by H3O+ and 31 by O2+ ionization. Overall, the fragmentation library facilitates enhanced compound identification and quantification in real-time PTR-MS spectra, while the TD-GC-EI-MS/PTR-MS platform provides a novel, robust, dual-detection platform for characterizing complex volatile mixtures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers