Analytical chemistry

A Versatile Aza-BODIPY-Based Activatable Probe for High-Contrast NIR-II Biosensing.

Chenzhi Yao, Liwen Huang, Qian He, Jiahao Guo, Shizhong Luo, Zhengchun Yin, Xingcai Zhang, Feng Gao,

Anhui Provincial Key Laboratory of Biomedical Materials and Chemical Measurement, Laboratory of Functionalized Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu241002, China. · Department of Ophthalmology, Eye & ENT Hospital, State Key Laboratory of Brain Function and Disorders, MOE Frontiers Center for Brain Science, Fudan University, Shanghai200031, China.

Key points

From the paper's conclusion
  • Collectively, these findings underscore the translational potential of the OBDP-2ClOH scaffold as a versatile and generalizable platform for the development of advanced activatable NIR-II probes.

Abstract

Activatable molecular probes in the second near-infrared (NIR-II, 900-1700 nm) window are sought-after for in vivo optical imaging and biosensing. However, current molecular skeletons are confined to a limited range of dye systems, including cyanine, hemicyanine, and xanthene derivatives. Herein, we report a series of ortho-halogenated phenol-conjugated aza boron dipyrromethene platforms (OBDP-xOH, where X = H, F, Cl, Br, or 2Cl) that achieve bright NIR-II emission through a pH-regulated intramolecular charge transfer mechanism. The optimized scaffold, OBDP-2ClOH (pKa = 6.1), concurrently demonstrates the NIR-II emission maximum at approximately 905 nm, a large Stokes shift of 117 nm, high NIR-II brightness (εmaxΦf>1000 nm ≈ 38.46 M-1 cm-1), and excellent photochemical stability. To validate the broad applicability of this platform, we further designed three target-activatable NIR-II nanoprobes responsive to UV light, H2S, and Cu2+, respectively. Each nanoprobe exhibited a high fluorescence turn-on ratio exceeding 29-fold and limits of detection below 10.3 nM. Leveraging these probes, we achieved rapid (<30 min) dynamic imaging of labile Cu2+ in the brains of Parkinson's disease models, as well as high-fidelity in vivo early detection of acute liver injury within 5 min, which is substantially faster than conventional clinical serum analysis that requires approximately 90 min. Collectively, these findings underscore the translational potential of the OBDP-2ClOH scaffold as a versatile and generalizable platform for the development of advanced activatable NIR-II probes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Versatile Aza-BODIPY-Based Activatable Probe for High-Contrast NIR-II Biosensing — Science Skim