A General Design of Compact "Zero-On" NIR-II Photoacoustic Dyes for High-Fidelity Imaging.
Chunxu He, Xi Li, Kai Chen, Qi Wang, Quli Fan, Xiaomei Lu, Yufu Tang
State Key Laboratory of Flexible Electronics (LoFE) & Institute of Advanced Materials (IAM), Nanjing University of Posts & Telecommunications, Nanjing, China. · Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM) and School of Flexible Electronics (Future Technologies), Nanjing Tech University (Nanjing Tech), Nanjing, China.
Key points
From the paper's conclusion- Near-infrared-II (1000-1700 nm) photoacoustic imaging enables deep-tissue visualization with high spatial precision but lacks organic probes integrating general design, reduced molecular complexity, and high-fidelity in vivo signal output.
Abstract
Near-infrared-II (1000-1700 nm) photoacoustic imaging enables deep-tissue visualization with high spatial precision but lacks organic probes integrating general design, reduced molecular complexity, and high-fidelity in vivo signal output. Herein, we present a general building-block design for ultralow-molecular-weight "zero-on" near-infrared-II photoacoustic dyes for in vivo high-fidelity imaging. Constructed around a dimethyl-dihydroacridine scaffold and synthesized in three steps, these dyes incorporate biomarker-responsive blocks for targeted activation and absorption-expanded blocks for near-infrared-II absorption tuning, while maintaining a molecular weight <500 Da. This general building-block design enables tailored applications. Ultralow molecular weight improves solubility, tissue penetration and clearance. Notably, biomarker activation drives nonconjugated-to-conjugated structural transition, inducing >700 nm absorption redshift and boosting near-infrared-II photoacoustic signals at 1064 nm from levels statistically indistinguishable from water (p > 0.05, defining "zero" probe background) to an 89.8-fold enhancement in "on" state. "Zero" background minimizes false positives from misinterpreting probe background accumulation signals in diseased tissues as biomarker activation, even in high-uptake organs like the liver. In a blinded study, our "zero-on" probes identified early‑stage hepatotoxicity in mice with 100% accuracy, outperforming 85% accuracy of traditional non-zero background "off-on" probes. This work enables a general design to achieve ultralow-molecular-weight near-infrared-II photoacoustic dyes for high-fidelity signal output in vivo.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short Wavelength Infrared Diimmonium Nano-Agents for Photoacoustic Imaging.Nature communications · 2026
- “Zero-On” NIR-II Photoacoustic Organic Nanoprobes for Ultra-Accurate Companion Diagnostics of Cancer Immunotherapy ResponseJournal of the American Chemical Society · 2026
- A Versatile Aza-BODIPY-Based Activatable Probe for High-Contrast NIR-II Biosensing.Analytical chemistry · 2026
- Molecular program design for 1064 nm light excited high‐contrast NIR‐IIb fluorescence imaging of murine vascularFlexMat · 2026
- Near-infrared photochromic miniprotein enables photoacoustic molecular imaging of acute inflammation and intracellular antigens.Nature methods · 2026
- Bright, Robust and Readily Accessible Fluorophore Family for NIR-II BioimagingJournal of the American Chemical Society · 2025