Analytical chemistry

Two-Point Calibration Surface Plasmon Resonance Immunoassay Enabled by Hadamard-Encoded Spectral Reconstruction and Deep Learning.

Youjun Zeng, Jun Yang, Chenglong Guo, Yan Chen, Fusheng Du, Leiming Wu, Shuwen Zeng, Yufeng Yuan

School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou510006, China. · School of Electronic Engineering and Intelligentization, Dongguan University of Technology, Dongguan523808, China.

Computational

Key points

From the paper's conclusion
  • Here, we report a Hadamard-encoded spectral compressive reconstruction (HSCR) platform coupled with a lightweight one-dimensional convolutional neural network (1D-SPRNet).

Abstract

Conventional surface plasmon resonance imaging (SPRi) relies on relative resonance-shift measurements and laborious multipoint calibration, rendering it incompatible with disposable-chip and point-of-care scenarios. Here, we report a Hadamard-encoded spectral compressive reconstruction (HSCR) platform coupled with a lightweight one-dimensional convolutional neural network (1D-SPRNet). By reframing chip-scale spatial nonuniformity as an in situ data-augmentation mechanism, the system generates ∼20,000 pixel-wise training spectra from a single measurement cycle and converts six compressed CMOS frames into quantitative refractive-index changes (ΔRIU) using only six multiplexed LED measurements. By outputting physical refractive-index units rather than arbitrary resonance shifts, the system eliminates the need for exhaustive chip-specific calibration: a minimal two-point Langmuir fit suffices for quantitative immunodetection. We demonstrate high-fidelity spectral recovery (Pearson correlation >0.999) and cross-chip generalization using NaCl refractive-index standards. In a rabbit IgG/goat antirabbit IgG model, the pretrained 1D-SPRNet achieves linear regression R2 = 0.996 in phosphate-buffered saline and R2 = 0.987 in 10-fold diluted human serum, with relative errors within ±7% in phosphate-buffered saline and recoveries ranging from 88.7% to 101.1% in 10-fold diluted human serum, along with negligible nonspecific adsorption. This integration of compressive spectral encoding with end-to-end deep regression enables high-throughput, real-time, minimal-calibration multiplexed biosensing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Two-Point Calibration Surface Plasmon Resonance Immunoassay Enabled by Hadamard-Encoded Spectral Reconstruction and Deep Learning — Science Skim