Learning-assisted full-spectrum refractive-index interrogation for a plasmonic photonic crystal fiber sensor modeled by the finite element method
Zhijun Gao, Yin-ting Chen, Yu Ying
Key points
From the paper's conclusion- These results demonstrate that full-spectrum interrogation can improve the numerical robustness of RI readout by using peak position, linewidth, slope, amplitude variation, and overall spectral morphology simultaneously.
Abstract
Reliable refractive-index (RI) interrogation in photonic-crystal-fiber surface-plasmon-resonance (PCF-SPR) sensors is commonly performed by resonance-wavelength tracking, which uses only one spectral feature and may become unstable under broad peaks, spectral distortion, or measurement perturbations. In this work, a heptagonal PCF-SPR sensor modeled by the finite element method (FEM) is used as the physical sensing platform, and a learning-assisted full-spectrum interrogation framework is proposed to estimate analyte RI from the complete confinement-loss profile. The sensor combines an asymmetric heptagonal air-hole lattice, an open analyte channel, and an inner gold coating to enhance coupling between the fundamental core mode and the surface plasmon polariton mode. The optimized structure operates over an RI range of 1.31--1.42 and achieves a maximum wavelength sensitivity of 12,400 nm per refractive-index unit (RIU). To reduce the cost of repeated FEM spectral scanning, a Fourier-enhanced residual surrogate is trained using spectrum-level train/validation/test partitioning. On the independent test set, the surrogate achieves a global root-mean-square error (RMSE) of 21.35 dB/cm, a global coefficient of determination (R²) of 0.87, and a mean peak-wavelength error of 6.7 nm. The trained surrogate is then embedded into a compensated full-spectrum inverse module, where candidate RI spectra are generated and matched with a target spectrum. Under clean-condition testing, the method achieves an RI mean absolute error (MAE) of 7.91×10⁻⁴ RIU, outperforming conventional peak-tracking and spectral-matching baselines. These results demonstrate that full-spectrum interrogation can improve the numerical robustness of RI readout by using peak position, linewidth, slope, amplitude variation, and overall spectral morphology simultaneously. Experimental fabrication and calibration remain necessary for practical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Smart SPR Biosensors: Machine Learning‐Augmented Dual‐Channel PCF TechnologyAdvanced Photonics Research · 2026
- Peak‐Aligned Gaussian‐Process‐Regression‐Assisted Plasmonic Refractive Index SensorInternational Journal of Optics · 2026
- Simultaneous dual-analyte detection biosensor through a stacking-based ensemble machine learning approach: design and optimizationBiomedical Optics Express · 2026
- A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine LearningInternational Journal of Optics · 2026
- Machine learning-driven optimization of monolithic gold plasmonic sensors: Achieving ultrahigh sensitivity with interpretable linear modelsPLoS ONE · 2026
- Taguchi-optimized suspended-core fiber SPR sensor with dual-interrogation performance analysis for broad-range RI detectionDiscover Sensors · 2026