Hadamard-encoded compressive principal component regression for rapid wavelength-scanning surface plasmon resonance imaging.
Qingwu Ma, Xiao Tang, Zhengqiang Yuan, Yujun Chen, Jun Yang, Chenglong Guo, Youjun Zeng
School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou, 510006, China. · State Key Laboratory of Hybrid Rice, Hunan Agricultural Equipment Research Institute, Hunan Academy of Agricultural Sciences, Changsha, 410125, China.
Key points
From the paper's conclusion- We report a Hadamard-encoded compressive principal component regression (HC-PCR) strategy integrated with a compact LED-array-based SPRi system.
Abstract
Surface plasmon resonance imaging (SPRi) enables label-free, high-throughput biomolecular analysis, yet conventional wavelength-scanning configurations rely on costly dispersive optics and broadband sources, suffering from prolonged acquisition, spectral broadening, and poor noise immunity at the resonance dip. We report a Hadamard-encoded compressive principal component regression (HC-PCR) strategy integrated with a compact LED-array-based SPRi system. Six narrowband LEDs are encoded through a Hadamard-style binary encoding matrix, allowing full spectral reconstruction from only six compressive intensity measurements per 162 ms cycle. A regularized least-squares inversion recovers the reflectance spectrum while avoiding the noise-vulnerable resonance dip. The PCR model then maps the reconstructed spectra directly to relative refractive index estimates within a low-dimensional principal-component subspace. Importantly, pixel-to-pixel spectral diversity induced by fabrication non-uniformities is harnessed to enrich the training set rather than suppressed as error. The system was calibrated using NaCl solutions and cross-chip validated across an extended concentration range with independently aligned resonance angles, achieving excellent quantitative agreement ( R 2 > 0.99 ). The HC-PCR mode achieves a detection resolution of 9.73 × 10 - 7 RIU and suppresses noise by approximately one order of magnitude relative to conventional resonance wavelength tracking. Furthermore, using a well-characterized rabbit IgG/goat anti-rabbit IgG binding system, the HC-PCR mode demonstrates superior quantitative linearity ( R 2 = 0.99276 ) compared to the resonance wavelength mode ( R 2 = 0.65554 ), and the extracted binding kinetics agree well with previously reported SPR values, validating the reliability of the system in real biomolecular interaction detection. This work establishes a cost-effective, rapid, and accurate approach for high-throughput SPRi refractive index mapping and biomolecular interaction analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two-Point Calibration Surface Plasmon Resonance Immunoassay Enabled by Hadamard-Encoded Spectral Reconstruction and Deep Learning.Analytical chemistry · 2026
- A low-cost, high-sensitivity WSPRi system using a multi-LED array and smoothness-constrained reconstruction algorithmApplied Physics Letters · 2026
- Theory of quantum-enhanced stimulated Raman scatteringQuantum Science and Technology · 2026
- Ultrafast Surface Plasmon Resonance Sensing via Dual‐Comb SpectroscopyLaser & Photonics Reviews · 2026
- Democratizing high-Q plasmonic optical fiber biosensing with low-resolution interrogation and Fourier demodulationCommunications Engineering · 2025
- Learning-assisted full-spectrum refractive-index interrogation for a plasmonic photonic crystal fiber sensor modeled by the finite element methodMeasurement Science and Technology · 2026