Augmenting ICP-OES Sensitivity for Trace Element Analysis in Crude Oil via High-Efficiency Micro-Ultrasonic Nebulization.
Junhang Dong, Shuyang Li, Gangzheng Sun, Wangang Zheng, Shenghui Yue, Pengju Xing, Yang Yu, Tao Liu,
Research Institute of Petroleum Engineering and Technology, Shengli Oilfield Company, SINOPEC, Dongying257000, Shandong, China. · Exploration and Development Research Institute, Shengli Oilfield Company, SINOPEC, Dongying257000, Shandong, China.
Key points
From the paper's conclusion- Overall, this study validates that employing MUN as a high-efficiency sample introduction system significantly elevates the analytical capabilities of ICP-OES, thereby facilitating the precise quantification of trace elements in complex energy and environmental matrices.
Abstract
Sensitive trace elements analysis in crude oil via inductively coupled plasma optical emission spectrometry (ICP-OES) is highly desirable for the petroleum industry. However, the conventional pneumatic nebulization (PN) sample introduction system suffers from extremely low nebulization efficiency (<5%), leading to inadequate sensitivity. Herein, a novel high-efficiency (∼85%) micro-ultrasonic nebulization (MUN) designed for ICP-OES was successfully developed. Under optimized conditions, MUN-ICP-OES achieved up to 17-fold sensitivity enhancements across 12 tested elements compared to conventional PN-ICP-OES, despite a 10-fold reduction in sample consumption. Notably, the MUN system permits independent adjustment of the carrier gas, lowering its flow rate extends aerosol residence time in the plasma, further boosting sensitivity without compromising nebulization efficiency. Furthermore, the MUN-ICP-OES demonstrated robust resistance to organic matrix interference and excellent long-term stability, achieving a relative standard deviation of 0.2% over 30 consecutive measurements using Ga as an internal standard. Compared to PN-ICP-OES, the limits of detection for the 12 elements in crude oils improved by 1-2 orders of magnitude. The accuracy of the proposed method was validated using a certified reference material, and results for actual crude oils showed excellent agreement with ICP-MS. Overall, this study validates that employing MUN as a high-efficiency sample introduction system significantly elevates the analytical capabilities of ICP-OES, thereby facilitating the precise quantification of trace elements in complex energy and environmental matrices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced Microplasma Excitation Source Using Fiber-Tip Discharge Clusters with Low Breakdown Voltage for Miniaturized Optical Emission Spectroscopy.Analytical chemistry · 2026
- A green sample preparation strategy for Cl and S determination in crude oil by ion chromatographyJournal of Chromatography A · 2026
- Ultrasound-assisted oxidative desulfurization of RFCC diesel: process intensification and statistical optimizationChemical Product and Process Modeling · 2026
- Enhancing LIBS detection of oil-borne metallic microparticles via acoustic manipulation chip-based enrichment.Lab on a chip · 2026
- Enhanced Electrolyte Atmospheric Liquid Discharge via Three-Dimensional Synergistic Effect for Trace Multielement Optical Emission SpectrometryAnalytical Chemistry · 2026
- Sample-Handling Bias and Direct ICP-MS of Ultratrace Metals in Semiconductor-Grade Isopropyl AlcoholACS Omega · 2026