Enhanced Electrolyte Atmospheric Liquid Discharge via Three-Dimensional Synergistic Effect for Trace Multielement Optical Emission Spectrometry
Hao Shen, Yi-Hao Xin, Jia-Nan Xu, Yong-Liang Yu, Shuang Liu
Key points
From the paper's conclusion- To address this issue, two pairs of point-discharge (PD) microplasmas were introduced beneath the main electrolyte atmospheric liquid discharge (EALD) channel to construct a square-pyramidal three-dimensional (3D) discharge configuration for the determination of Cd, Zn, Hg, and Pb in environmental and food samples.
Abstract
In liquid direct-introduction microplasma optical emission spectrometry (OES) systems, limited energy deposition near the liquid interface restricts the achievement of low detection limits and sensitive multi-element analysis. To address this issue, two pairs of point-discharge (PD) microplasmas were introduced beneath the main electrolyte atmospheric liquid discharge (EALD) channel to construct a square-pyramidal three-dimensional (3D) discharge configuration for the determination of Cd, Zn, Hg, and Pb in environmental and food samples. This configuration enabled multiple discharge units to act on the same solution region from different directions, thereby reconstructing the discharge profile near the liquid interface and expanding the effective emission region and interaction range. The spatial expansion of the emission region was consistent with the enhanced spectral response, while the higher OES responses maintained under equal total input power further supported the contribution of the 3D discharge configuration to the analytical enhancement. Compared with conventional EALD-OES, the proposed 3D-EALD-OES system enhanced the emission intensities of Cd, Zn, Hg, and Pb by factors of 5.4, 3.5, 3.5, and 2.4, respectively. Under optimized conditions, the limits of detection (LODs) were reduced from 0.3, 1.6, 1.5, and 3.9 μg L−1 to 0.08, 0.5, 0.2, and 1.9 μg L−1, respectively, with relative standard deviations below 4%. The accuracy and applicability of the system were validated by the analysis of certified reference materials and real samples. This 3D structural-modulation enhancement strategy provided a feasible pathway for improving the performance of discharge microplasma-driven miniaturized OES systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced Microplasma Excitation Source Using Fiber-Tip Discharge Clusters with Low Breakdown Voltage for Miniaturized Optical Emission Spectroscopy.Analytical chemistry · 2026
- A compact short-path electrothermal vaporization-atmospheric pressure glow discharge atomic emission spectrometry device for the determination of cadmium and lead.Analytical methods : advancing methods and applications · 2026
- Signal enhancement in laser-induced breakdown spectroscopy for improved sensitivity and detection limits: Mechanisms and prospects.The Review of scientific instruments · 2026
- A Forensic Perspective of Electric Field Enhanced Signal Sensitivity and Repeatability of Laser Induced Breakdown Spectroscopy (LIBS) for Industrial Grade Al-Si Alloy.Applied spectroscopy · 2026
- Microplasma glow discharge chip for open-air atomic emission spectroscopyJournal of Micromechanics and Microengineering · 2026
- Electric field assisted LIBS for multi-element analysis of human dental enamel: Signal enhancement and calibration-free quantification.Talanta · 2026