Anatomy-guided selection of single-versus dual-arc VMAT for localised prostate cancer using novel geometric complexity metrics
Ghaith Mohammad Abdoun Al-Ma’mouri, MohammadReza Khademi, Iraj Abedi
Key points
From the paper's conclusion- Introduction: This study compared single-arc (SA) and dual-arc (DA) VMAT for localised prostate cancer using an integrated assessment of dosimetric, radiobiological, deliverability, complexity and anatomical factors and evaluated whether anatomy-based metrics (Mq,r index and F metric) can predict patients benefiting from DA-VMAT.
Abstract
Introduction: This study compared single-arc (SA) and dual-arc (DA) VMAT for localised prostate cancer using an integrated assessment of dosimetric, radiobiological, deliverability, complexity and anatomical factors and evaluated whether anatomy-based metrics (Mq,r index and F metric) can predict patients benefiting from DA-VMAT. Methods: Forty-five patients with localised prostate cancer (cT1–T2, N0, M0) were retrospectively analysed. SA and DA-VMAT plans (78 Gy/39 fractions) were generated using Monaco. Comparisons included dose-volume histogram (DVH) metrics, homogeneity and conformity indices, gEUD, TCP and NTCP. Plan deliverability was assessed using monitor units (MUs), beam-on time, modulation complexity score (MCSv) and gamma analysis. The Mq,r index (PTV–OAR spatial relationship) and F metric (anatomical confinement) were analysed for correlation with DA benefit and predictive ability using ROC analysis. Results: Target coverage was comparable between the two techniques (PTV D95%: 74·2 vs 74·5 Gy, p = 0·21). DA-VMAT improved homogeneity (p = 0·03) and reduced the rectal dose (V40Gy: 35·2% vs. 38·1%; V65Gy: 18·4% vs. 21·3%), resulting in a modest NTCP reduction (4·8% vs. 3·9%). However, DA-VMAT increased the MUs (542 vs. 426), beam-on time (152 vs. 118 s) and complexity (MCSv: 0·72 vs. 0·84; all p < 0·01). Both Mq,r and F correlated with NTCP reduction ( ρ = 0·63 and −0·58) and showed good discrimination (AUC: 0·81 and 0·79). Conclusion: DA-VMAT provides modest improvements in rectal sparing and homogeneity but increases complexity and treatment time. Anatomy-based metrics may support personalised arc selection and warrant prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dosimetric and robustness comparison of single- and double-arc volumetric-modulated arc therapy incorporating avoidance structures for prostate cancer with simulated bilateral hip prostheses.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Machine learning-based prediction of gamma passing rates in VMAT prostate external radiation therapy plans.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- A Unified Planning Platform Comparison of VMAT, Helical Tomotherapy, and IMRT in Nasopharyngeal Carcinoma: Dosimetric Superiority and Organ Sparing AnalysisTechnology in Cancer Research & Treatment · 2026
- RapidArc dynamic versus IMRT and VMAT for endometrial cancer SIB radiotherapy.Radiation oncology (London, England) · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Statistical process control and error curve modelling identify superior pre-treatment verification metrics for nasopharyngeal carcinoma and cervical cancer VMAT: a retrospective studyFrontiers in Oncology · 2026