Journal of Radiotherapy in Practice

Anatomy-guided selection of single-versus dual-arc VMAT for localised prostate cancer using novel geometric complexity metrics

Ghaith Mohammad Abdoun Al-Ma’mouri, MohammadReza Khademi, Iraj Abedi

Observational

Key points

From the paper's conclusion
  • Introduction: This study compared single-arc (SA) and dual-arc (DA) VMAT for localised prostate cancer using an integrated assessment of dosimetric, radiobiological, deliverability, complexity and anatomical factors and evaluated whether anatomy-based metrics (Mq,r index and F metric) can predict patients benefiting from DA-VMAT.

Abstract

Introduction: This study compared single-arc (SA) and dual-arc (DA) VMAT for localised prostate cancer using an integrated assessment of dosimetric, radiobiological, deliverability, complexity and anatomical factors and evaluated whether anatomy-based metrics (Mq,r index and F metric) can predict patients benefiting from DA-VMAT. Methods: Forty-five patients with localised prostate cancer (cT1–T2, N0, M0) were retrospectively analysed. SA and DA-VMAT plans (78 Gy/39 fractions) were generated using Monaco. Comparisons included dose-volume histogram (DVH) metrics, homogeneity and conformity indices, gEUD, TCP and NTCP. Plan deliverability was assessed using monitor units (MUs), beam-on time, modulation complexity score (MCSv) and gamma analysis. The Mq,r index (PTV–OAR spatial relationship) and F metric (anatomical confinement) were analysed for correlation with DA benefit and predictive ability using ROC analysis. Results: Target coverage was comparable between the two techniques (PTV D95%: 74·2 vs 74·5 Gy, p = 0·21). DA-VMAT improved homogeneity (p = 0·03) and reduced the rectal dose (V40Gy: 35·2% vs. 38·1%; V65Gy: 18·4% vs. 21·3%), resulting in a modest NTCP reduction (4·8% vs. 3·9%). However, DA-VMAT increased the MUs (542 vs. 426), beam-on time (152 vs. 118 s) and complexity (MCSv: 0·72 vs. 0·84; all p < 0·01). Both Mq,r and F correlated with NTCP reduction ( ρ = 0·63 and −0·58) and showed good discrimination (AUC: 0·81 and 0·79). Conclusion: DA-VMAT provides modest improvements in rectal sparing and homogeneity but increases complexity and treatment time. Anatomy-based metrics may support personalised arc selection and warrant prospective validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Anatomy-guided selection of single-versus dual-arc VMAT for localised prostate cancer using novel geometric complexity metrics — Science Skim