MRI-only workflow for preclinical ion beam therapy: Deep-learning-based synthetic CT generation from ultra-high-field small animal MRI.
Isselmou Abdarahmane, Silvia Stocchiero, Lorenz Wolf, Gerd Heilemann, Barbara Knäusl, Lukas Zimmermann, Markus Zeilinger, Dietmar Georg,
Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; Competence Center for Preclinical Imaging and Biomedical Engineering, Faculty of Health, University of Applied Sciences, Johannes-Gutenberg-Straße 3, A-2700 Wiener Neustadt, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria. · Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria.
Key points
From the paper's conclusion- This study demonstrated the feasibility of MRI-only treatment planning for preclinical brain irradiation using a U-Net-based sCT generator, reducing the need for dedicated µCT acquisitions. However, limited training data due to ethical constraints challenges cross-cohort generalization, while a rigidly aligned sCTavg provided competitive performance but requires an additional registration step.
Abstract
PURPOSE: To develop and validate a deep-learning-based magnetic resonance imaging (MRI)-only workflow for preclinical mouse brain irradiations with ion beams and to compare with a rigidly aligned population-averaged CTs (sCTsavg). METHODS: A 3D U-Net was trained on 69 paired ultra-high-field (15.2T) T1-weighted MRIs and micro-CTs (µCTs) from 17 BALB/c mice. Two BALB/c and two C57BL/6 mice were used for independent testing. Two training losses were compared and selected based on cross-validation. Quantitative performance was assessed using mean absolute error (MAE), structural similarity index (SSIM), and bone Dice similarity coefficient (DSC). Treatment plans with X-rays, protons, and carbon ions were analyzed using dose-volume parameters and 3D gamma analysis of the physical dose distribution. RESULTS: For image generation, the intra-strain test set reached an MAE of (138±10)HU and a bone DSC of 0.75-0.80, slightly below the sCTavg baseline (0.79-0.80). On the inter-strain test set (C57BL/6), the results were inferior (DSC: 0.59--0.64), while the sCTavg retained a DSC of 0.70-0.77. The dose distributions were comparable between plans calculated on the U-Net-based synthetic CT (sCTUNet) and on the µCT. The largest deviation occurred in the near-maximum bone dose (D2%) with 0.16Gy for both, protons and for carbon ions. CONCLUSIONS: This study demonstrated the feasibility of MRI-only treatment planning for preclinical brain irradiation using a U-Net-based sCT generator, reducing the need for dedicated µCT acquisitions. However, limited training data due to ethical constraints challenges cross-cohort generalization, while a rigidly aligned sCTavg provided competitive performance but requires an additional registration step.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical implementation of deep learning-based synthetic CT for MRI-only volumetric modulated arc therapy in head and neck and pelvic cancer patientsRadiation Oncology · 2025
- MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and ProtontherapyarXiv · 2026
- Impact of multisequence MRI on deep learning-based dose prediction for glioblastoma radiotherapy: A comparative evaluation of CT-only and CT+MRI models.Radiography (London, England : 1995) · 2026
- Evaluation of U-Net Based Architectures for Synthetic CT Generation from Dual-Contrast MRI.Biomedical physics & engineering express · 2026
- Application of synthetic computed tomography based on a deep learning model in pelvic radiotherapy planning: A feasibility study.Journal of applied clinical medical physics · 2026
- Clinical application of MR-Only in cyberknife stereotactic radiotherapy for brain metastases: a feasibility study.Radiation oncology (London, England) · 2026