Evaluation of U-Net Based Architectures for Synthetic CT Generation from Dual-Contrast MRI.
Sajede Mousavi, Alireza Sadremomtaz
University of Guilan, namjoo avenue, Rasht, Gilan, 1918, Iran (The Islamic Republic of). · Department of Physics, University of Guilan, physics department faculty of science namjoo avenue Guilan university Rasht Iran, Rasht, 1918, Iran (The Islamic Republic of).
Key points
From the paper's conclusion- This study demonstrates the value of combining residual and attention modules in the same architecture, along with dual-contrast MRI input, for improved sCT accuracy and stability.
Abstract
Deep learning, especially U-Net-based models, has become the dominant approach for synthetic CT (sCT) generation for MRIonly radiotherapy and PET/MR attenuation correction. However, the field lacks direct comparisons of different U-Net variants under identical conditions. In this study, we evaluated five U-Net-based architectures, U-Net, ResU-Net, Attention U-Net, U-Net++, and attention deep residual U-Net (ADR-U-Net) for generating sCT from paired T1-weighted and FLAIR brain MRI. All models were trained on the same dataset using the same input format, preprocessing pipeline, architecture depth, optimizer, loss function, and training setup. A combined loss of mean absolute error (MAE) and Structural Similarity Index Measure (SSIM) was used. Performance was assessed at both voxel and patient levels using Root Mean Square Error (RMSE), Peak Signal-to-Noise Ratio (PSNR), MAE, and SSIM. All models successfully produced pseudo-CT images. Among them, ADR-U-Net achieved the best performance, with the lowest MAE (35.3 HU) and RMSE (87.2 HU), and the highest SSIM (0.923) and PSNR (36.4 dB). Qualitative results showed that all networks preserved brain structure, while ADR-U-Net was more accurate near bone-air interfaces. Patient-wise analysis also confirmed its superior consistency and robustness. This study demonstrates the value of combining residual and attention modules in the same architecture, along with dual-contrast MRI input, for improved sCT accuracy and stability. These findings provide guidance for selecting and developing deep learning models in MRI-only radiotherapy and PET/MR workflows. Future work may include clinical validation, incorporation of pathological cases, and extension to 3D or dose-aware models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and ProtontherapyarXiv · 2026
- Generative structure-guided denoising diffusion probabilistic model for MR to CT image synthesis in radiotherapy planning.Physics in medicine and biology · 2026
- MRI-only workflow for preclinical ion beam therapy: Deep-learning-based synthetic CT generation from ultra-high-field small animal MRI.Zeitschrift fur medizinische Physik · 2026
- Evaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a technical note.Radiological physics and technology · 2026
- DAFNet: Dual-path Adaptive Fusion Network for High-Fidelity Cross-Modality Brain MR Image SynthesisarXiv · 2026
- Uncertainty-Aware Simultaneous Synthesis and Segmentation Via Evidential Deep Learning.IEEE journal of biomedical and health informatics · 2026