Key points

From the paper's conclusion
  • We then summarize optical, electrochemical, and other sensing modalities that achieve limits of detection (LODs) at or below current U.S.

Abstract

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants whose effective analysis, characterization, and remediation heavily rely on sensitive, reliable, and field-deployable monitoring technologies. Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) remains the benchmark for PFAS analysis, its reliance on centralized laboratories, specialized instrumentation, and extensive sample preparation limits its utility for rapid screening and on-site decision making. This review critically evaluates recent progress in non-mass-spectrometry PFAS sensors from the perspective of field deployment. We first define key design criteria for practical PFAS sensing, including regulatory-relevant sensitivity, selectivity, matrix tolerance, stability, and portability. We then summarize optical, electrochemical, and other sensing modalities that achieve limits of detection (LODs) at or below current U.S. Environmental Protection Agency (EPA) drinking water limits for perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), highlighting the recognition and signal-transduction strategies that enable ultralow PFAS detection. Beyond regulatory-relevant sensitivity, we discuss emerging trends in PFAS sensing, including emerging PFAS recognition mechanisms, detection of emerging, short and ultrashort chain PFAS, ratiometric quantification, PFAS differentiation, and smartphone-assisted readouts. Finally, we highlight persistent barriers to on-site PFAS sensing, including inconsistent LOD/LOQ reporting, limited assessment of specificity and selectivity, and challenges in translating laboratory proof-of-concept sensors into credible tools for routine field monitoring. Rather than replacing LC-MS/MS, field-deployable PFAS sensors are best positioned as complementary tools for rapid screening, source tracking, treatment monitoring, and early-warning detection. Future advances will require standardized performance evaluation, mechanism-guided sensor design, realistic field validation, and integration with portable data-processing platforms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers