Talanta

Highly efficient electrochemical detection of cholesterol via hydrophobic matching host-guest recognition on bimetallic nanoparticle support.

Xin-Peng Qi, Xue Gao, Hao Li, Zhencheng Chen, Xiao-Zhen Feng, Guo-Cheng Han, Yueneng Yi

School of Life and Environmental Sciences, Guangxi Human Physiological Information Non Invasive Detection Engineering Technology Research Center, Guangxi Key Laboratory of Metabolic Reprogramming and Intelligent Medical Engineering for Chronic Diseases, Guangxi Colleges and Universities Key Laboratory of Biomedical Sensors and Intelligent Instruments, Guilin University of Electronic Technology, Guilin, 541004, PR China. · School of Life and Environmental Sciences, Guangxi Human Physiological Information Non Invasive Detection Engineering Technology Research Center, Guangxi Key Laboratory of Metabolic Reprogramming and Intelligent Medical Engineering for Chronic Diseases, Guangxi Colleges and Universities Key Laboratory of Biomedical Sensors and Intelligent Instruments, Guilin University of Electronic Technology, Guilin, 541004, PR China. Electronic address: fxz97118@guet.edu.cn.

Key points

From the paper's conclusion
  • Hence, fabricating CHO biosensors possesses profound research implications.

Abstract

Cholesterol (CHO) wields profound significance in basic cell life activities. Hence, fabricating CHO biosensors possesses profound research implications. In this work, β-cyclodextrin (β-CD) was employed as the recognition element based on its specific host-guest recognition interaction with CHO, while ferrocenylformic acid (Fc(COOH)) served as the electrochemical signal probe. Nickel nanoparticles (NiNPs) were deposited by cyclic voltammetry (CV) and gold nanoparticles (AuNPs) were deposited by time-current method (i-t) to construct a β-CD/AuNPs/NiNPs/GCE sensor for CHO detection. The signal intensity of the electrochemical probe was measured and recorded using the differential pulse voltammetry (DPV) method, the peak current of the DPV shows a gradual downward trend as the CHO concentration increases. The constructed sensor achieved a linear detection range of 50.00-1000.00 nM, an ultra-low limit of detection (LOD) of 16.70 nM, and a high sensitivity of 0.00526 μA cm-2 nM-1. The sensor showed good selectivity and long-term stability over 10 days. It was used for the actual detection of CHO in human serum. The recovery rate was between 97.46-103.57%, and the relative standard deviation (RSD) was less than 3.62%, showing a good practical application prospect.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers