Analytical and bioanalytical chemistry

An enantioselective strategy for the recognition of vitamin C enantiomers based on an electrochemical NPG/PCN-224-L-Cys chiral interface sensor.

Xi Wu, Chenggang Geng, Lihua Zhou, Weiwei Cheng, Zhenjiong Wang, Yan Zhang, Di Wu, Linghan Meng,

College of Food Science and Engineering/Collaborative Innovation Center for Modern Grain Circulation and Safety/Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, 210023, China. · Changzhou Food and Drug Fiber Quality Supervision and Inspection Center, Changzhou, 213000, China.

Key points

From the paper's conclusion
  • The findings of this work lay technical foundation for the rapid determination of Vc enantiomers and are of significance for sensing other chiral molecules.

Abstract

The highly similar chemical structures of L-ascorbic acid (L-Vc) and D-ascorbic acid (D-Vc) render it difficult to quantify. In this study, a novel enantioselective chiral electrochemical sensor based on NPG/PCN-224-L-Cys was developed for the recognition of Vc enantiomers. Nanoporous gold (NPG) film was coated on the glassy carbon electrode (GCE) surface to improve the electrocatalysis activity and provide a porous substrate. L-Cysteine (L-Cys)-functionalized PCN-224 was then added onto the NPG film to form a chiral electrode by the Au-S bonds. Upon the introduction of Cu2+, a sandwich complex of L-Cys@Cu2+@D-Vc was formed, while L-Vc cannot form such a complex because of the steric hindrance caused by the chiral electrode interface. The formation of L-Cys@Cu2+@D-Vc led to a significant current decrease in the ferricyanide probe, thereby realizing the enantioselective recognition of different Vc enantiomers on the electrode surface. The porous structure of chiral MOF provided abundant chiral binding sites. The optimized chiral NPG/PCN-224-L-Cys/GCE sensor exhibited outstanding detection performance towards D-Vc with a wide linear range of 5-25 μM and low detection limit of 0.95 μM (signal-to-noise ratio = 3). The fabricated chiral electrochemical sensor demonstrated outstanding stability, reproducibility, and anti-interference capabilities. And desirable recovery rates varying from 86.2 to 118.6% were obtained for real lime juice samples based on the fabricated NPG/PCN-224-L-Cys/GCE sensor demonstrating its practical applicability. The findings of this work lay technical foundation for the rapid determination of Vc enantiomers and are of significance for sensing other chiral molecules.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers