A novel, cost-efficient and sinusoidal voltage-based amperometric biosensor integrated into a 3D-printed microfluidic system for glucose determination in untreated blood and serum plasma.
Marina Jiménez-Rodríguez, Álvaro Jesús Sainz-Calvo, Juan José García-Guzmán, Laura Cubillana-Aguilera, José María Palacios-Santander, Dolores Bellido-Milla
Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, Puerto Real, 11510, Cádiz, Spain. · Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, Puerto Real, 11510, Cádiz, Spain. Electronic address: juanjo.garciaguzman@uca.es.
Key points
From the paper's conclusion- A new amperometric biosensor integrated into a 3D-printed microfluidic platform has been developed and evaluated for the determination of glucose in untreated human serum and plasma.
Abstract
A new amperometric biosensor integrated into a 3D-printed microfluidic platform has been developed and evaluated for the determination of glucose in untreated human serum and plasma. Integrating alternative sinusoidal electrochemical growth methods with advanced polymer-based transducers and microfluidic architectures represents a significant trend in improving clinical biomonitoring systems. The sensing platform uses Sonogel-Carbon (SNG-C) as the electrochemical transducer substrate, sequentially modified through layer-by-layer assembly. Initially, a film of Prussian Blue (PB) was deposited onto the surface to act as an efficient redox mediator. Subsequently, glucose oxidase (GOx) was immobilized by entrapment during the electrochemical growth of a poly(3,4-ethylenedioxythiophene) (PEDOT) by using sinusoidal voltages. Finally, it incorporates a multipolymeric diffusion membrane containing polyurethane (PU) and Nafion that limits glucose access to the enzyme. Under continuous flow conditions, a high sensitivity of 0.39 μA mM-1 cm-2 was obtained for this electrode in a linear range of 1.5 - 45 mM (R2 = 0.9951), with a low detection limit (LOD) of 0.36 mM. This biosensor also showed good repeatability (RSD = 2.74%, n = 4) and reproducibility (RSD = 2.63%, n = 4). Additionally, it exhibited high selectivity (no observation of significant interferences by interfering species such as ascorbic acid, uric acid, urea, dopamine, bovine serum albumin (BSA), lactate, NaCl, CaCl2 and KCl). Finally, the platform was successfully validated through the real-time monitoring of glucose in both synthetic and untreated human clinical samples using the additively manufactured polyethylene terephthalate glycol (PETG) microfluidic platform, featuring an optimized microfluidic volume about 280 μL. The analytical results demonstrated an excellent correlation with standard hospital reference methodologies, confirming the system reliability. These findings underscore the potential of this microfluidic electrochemical tool as a robust, precise, and cost-effective solution for near-patient biomedical monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Amperometric Glucose Biosensor Based on NiPtPd Nanozyme and Glucose Oxidase.Micromachines · 2026
- Nanostructured copper/cobalt tungstate/poly(aniline-co-pyrrole) hybrid electrode for high-performance enzymatic glucose biosensing.Talanta · 2026
- A self-calibrating microelectrode chip for glucose sensing in whole sturgeon blood.The Analyst · 2026
- Digital-Based Potentiostat and Mesoporous Microelectrode Co-Design for Non-Enzymatic Glucose Detection at 0.3V- VDD and 1.65nW-Power.IEEE transactions on biomedical circuits and systems · 2026
- Integrated extraction-detection platform based on Pt-Cu@PDA-rGO enzyme-free electrodes and porous microneedles for glucose monitoring.International journal of pharmaceutics · 2026
- Ni-Cu-Zn Prussian Blue Analogue Nanozyme-Based Cascade Colorimetric Platform for Glucose Detection.Journal of fluorescence · 2026