Nanostructured copper/cobalt tungstate/poly(aniline-co-pyrrole) hybrid electrode for high-performance enzymatic glucose biosensing.
Amany M Sawy, Badawi Anis, Fatma B Rashidi, Safaa S Hassan, Rabeay Y A Hassan
Biosensors Research Lab, Zewail City of Science and Technology, 6th October City, Giza, 12578, Egypt; Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt. · Faculty of Applied Health Sciences Technology, Nile Valley University, Fayoum, 63518, Egypt; Spectroscopy Department, Physics Research Institute, National Research Centre, Dokki, 12622, Giza, Egypt.
Key points
From the paper's conclusion- These findings highlight the potential of the Cu/CoWO4@PANi-co-PPy-based platform as a promising strategy for high-performance glucose sensing and for the development of miniaturized electrochemical point-of-care devices.
Abstract
Despite significant advances in electrochemical glucose biosensors, achieving a broad linear dynamic range, rapid response time, and high selectivity remains a challenge. In this study, we report a newly designed enzymatic glucose biosensor based on a binary metal tungstate (copper/cobalt) coupled with a conductive poly(aniline-co-pyrrole) nanocomposite (Cu/CoWO4@PANi-co-PPy) on a modified screen-printed electrode. The nanocomposite architecture provides rapid electron transfer and a high electroactive surface area, enabling efficient immobilization of glucose oxidase (GOx) via a chitosan/glutaraldehyde cross-linked network. The resulting disposable printed biosensor chips demonstrated a rapid response time of 8.0 s, a wide linear detection range of 0.005- 35 mM, and a low detection limit of 0.4 μM. Under steady-state conditions, the biosensor followed Michaelis-Menten kinetics with an apparent Km of 0.30 mM, indicating high enzyme affinity and activity. Furthermore, the platform exhibited excellent selectivity, reproducibility, and long-term stability, maintaining high resistance to interference during glucose detection. The practical utility of the proposed biosensor was further evaluated using spiked human serum samples, demonstrating reliable analytical performance in complex biological matrices. These findings highlight the potential of the Cu/CoWO4@PANi-co-PPy-based platform as a promising strategy for high-performance glucose sensing and for the development of miniaturized electrochemical point-of-care devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Amperometric Glucose Biosensor Based on NiPtPd Nanozyme and Glucose Oxidase.Micromachines · 2026
- Copper oxide nanoparticle/stainless steel hybrid structures for non-enzymatic glucose detection.Nanoscale advances · 2026
- A Naphthalenediimide‐Bridged Donor–Acceptor Polymer for Electrochemical Glucose BiosensingJournal of Applied Polymer Science · 2026
- Construction and Evaluation of an Enzyme-Free Glucose Sensor Based on CuO/Porous Nitrogen-Doped Graphene Nanocomposites: Integration of Nanomaterial-Oriented Research into an Undergraduate Laboratory ExperimentJournal of Chemical Education · 2026
- Scalable Fabrication of Stainless Steel-CuO Hybrid Nanostructured Electrodes for Nonenzymatic Glucose Sensing.ACS omega · 2026
- Copper-doped mesoporous silica nanoparticles for constructing a single-particle enzyme-nanozyme cascade sensing system.Mikrochimica acta · 2026