A Retrospective Study on High-Flow Nasal Cannula Oxygen Therapy for Acute Hypoxemic Respiratory Failure: Clinical Characteristics and Treatment Failure Predictors.
Mengyi Wang, Jie Gao, Hong Chen, Hanhan Hong
Department of Respiratory and Critical Care Medicine, The Second Affiliated Hospital of Naval Medical University, Shanghai 200003, China. · Department of Respiratory and Critical Care Medicine, The Second Affiliated Hospital of Naval Medical University, Shanghai 200003, China. Electronic address: hhh18321099688@163.com.
Key points
From the paper's conclusion- The eight-predictor model showed good discrimination and acceptable internally validated calibration. External validation is required before clinical implementation.
Abstract
OBJECTIVE: To characterize HFNC use in AHRF, identify factors associated with treatment failure, and develop a prediction model. METHODS: This retrospective study included 350 patients receiving HFNC for the first time between October 2023 and December 2025; 82 experienced treatment failure and 268 succeeded. Eight candidate predictors were selected based on univariable associations, clinical relevance, confounding, information overlap, and events per parameter, and all were entered into multivariable logistic regression. Restricted cubic splines assessed nonlinear associations. Performance was evaluated by discrimination, calibration, 1,000-resample bootstrap validation, and decision curve analysis (DCA). RESULTS: The final model included age, cardiovascular disease, APACHE II score, AHRF etiology, RALE score, ROX index, heart rate (HR), and thoracoabdominal asynchrony. Higher APACHE II (OR = 1.217, 95% CI: 1.126-1.315), extrapulmonary etiology (OR = 2.444, 95% CI: 1.061-5.631), and higher RALE score (OR = 1.121, 95% CI: 1.053-1.194) were associated with increased odds of failure, whereas higher ROX index was associated with lower odds (OR = 0.239, 95% CI: 0.157-0.363). HR showed a nonlinear association (P for nonlinearity = 0.018). The apparent and bootstrap-corrected C-indices were 0.912 and 0.899, respectively. The optimism-corrected calibration intercept and slope were -0.077 and 0.895, and the corrected Brier score was 0.102. DCA indicated clinical net benefit across evaluated thresholds. CONCLUSION: The eight-predictor model showed good discrimination and acceptable internally validated calibration. External validation is required before clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a predictive model for high-flow nasal cannula treatment failure in emergency department patients with acute heart failure: a retrospective secondary data analysis.Journal of Korean biological nursing science · 2026
- "Accuracy of ROX, Pediatric-Specific Indices and Their Temporal Trends in Predicting High-Flow Nasal Cannula Failure in Children With Acute Respiratory Distress".Pediatric pulmonology · 2026
- ROX vs. HACOR: early prediction of HFNC failure in ICU patients admitted from the emergency department with lung cancer-related hypoxemia.BMC pulmonary medicine · 2026
- Prospective validation of HACOR score for HFNO failure in emergency department patients with acute respiratory failure.The American journal of emergency medicine · 2026
- Clinical Predictors of High-Flow Nasal Cannula Failure in Children with Acute Respiratory Illness: A Single-Center Experience.Indian journal of pediatrics · 2026
- Comparison of HACOR score and ROX index for predicting noninvasive ventilation failure in acute hypoxemic respiratory failure: a prospective study.Irish journal of medical science · 2026