Pediatric pulmonology

"Accuracy of ROX, Pediatric-Specific Indices and Their Temporal Trends in Predicting High-Flow Nasal Cannula Failure in Children With Acute Respiratory Distress".

Rattakarn Yuwattana, Wicharn Boonjindasup, Watit Niyomkarn, Lalida Kongkiattikul, Nuttida Panichapat, Rujipat Samransamruajkit

Department of Pediatrics, Division of Pediatric Critical Care, Faculty of Medicine, Chulalongkorn University, Bangkok, Province, Thailand.

Key points

From the paper's conclusion
  • CRS is the most robust independent predictor of pediatric HFNC failure, while the ROX and p-ROX indices serve as valuable objective parameters. Using these objective parameters can help early detection of HFNC non-responders, potentially reducing pediatric morbidity and mortality.

Abstract

INTRODUCTION: High-Flow Nasal Cannula (HFNC) therapy is widely used for pediatric acute respiratory distress; however, the absence of objective predictors for treatment failure remains a significant clinical challenge. Delayed recognition of failure can lead to increased morbidity and mortality. This study aim to evaluate the predictive accuracy of respiratory rate-oxygenation (ROX) index, change of ROX index, pediatric ROX (p-ROX) index, and Clinical respiratory score (CRS) in identifying children at risk of HFNC treatment failure. MATERIALS AND METHODS: This study, conducted from February 2025 to April 2026, enrolled 105 pediatric patients (age < 18 years) with acute respiratory distress treated with HFNC. Patients with chronic lung or heart disease were excluded. Demographic and clinical data, including the CRS, p-ROX, ROX index and its trend, were evaluated at baseline and at 1, 4, and 12 h after HFNC initiation. RESULTS: The HFNC failure rate was 15%, with Lower respiratory tract infection as the most prevalent diagnosis (74.3%). Predictors for HFNC were ROXinitial ≤ 9.77 (sensitivity 81.3%, specificity 64.8%, AUC: 0.73) and ROX12 h ≤ 7.10 (sensitivity 71.4%, specificity 64.8%, AUC: 0.68). p-ROX12 h ≤ 219 (sensitivity 85.7%, specificity 62.5%, AUC: 0.74). The ∆ROX 1→12 emerged as an independent predictor of failure with cut-off value ≤ 0.29 (sensitivity 85.7%, specificity 62.5%, AUC: 0.71). The CRSinitial ≥ 5 and CRS1,4,12 ≥ 4 had high specificity (85%-95%, AUC: 0.71-0.86). CONCLUSION: CRS is the most robust independent predictor of pediatric HFNC failure, while the ROX and p-ROX indices serve as valuable objective parameters. Using these objective parameters can help early detection of HFNC non-responders, potentially reducing pediatric morbidity and mortality.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers