Resuscitation

Reversed airflow during asynchronous volume controlled mechanical ventilation in Out-of-Hospital Cardiac Arrest: a physiological observational study.

Christophe Duchatelet, Marie Vergotte, Thomas Tackaert, Maxim Vanwulpen, Said Hachimi-Idrissi

Faculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium; Department of Emergency Medicine, Ghent University Hospital, Corneel Heymanslaan 10, Ghent, Belgium. Electronic address: christophe.duchatelet@uzgent.be. · Faculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium; Department of Emergency Medicine, Ghent University Hospital, Corneel Heymanslaan 10, Ghent, Belgium.

Observational

Key points

From the paper's conclusion
  • Reversed airflow occurred frequently during asynchronous volume-controlled mechanical ventilation with the Oxylog 3000 in intubated out-of-hospital cardiac arrest patients receiving continuous manual chest compressions. Its physiological and clinical implications require further investigation.

Abstract

AIM: Chest compressions during the inspiratory phase of a ventilation can force air out of the lungs, so-called reversed airflow. Human data on this phenomenon during mechanical ventilation are lacking. We aimed to quantify its frequency and magnitude during asynchronous mechanical ventilation in intubated adult out-of-hospital cardiac arrest patients receiving continuous chest compressions. METHODS: This single-centre descriptive cross-sectional study used prospectively collected data from patients treated by a physician-staffed prehospital team. After tracheal intubation, patients were ventilated with an Oxylog 3000 transport ventilator in volume-controlled mode without positive end-expiratory pressure, during continuous manual chest compressions. Intratracheal pressures recorded via two catheters allowed calculation of airflow and ventilation parameters during the first minute after intubation. Reversed airflow was defined as expiratory airflow during the inspiratory phase of a mechanical breath. Continuous data are reported as median (first-third quartile). RESULTS: Twelve patients were included (median age 68 years [62-75]; 7 [58.3%] male), of whom 5 (41.7%) achieved sustained return of spontaneous circulation. Reversed airflow occurred in 10 (83.3%; 95% CI 55.2-95.3) patients and in 141 of 172 (82.0%; 95% CI 75.6-87.0) analysed ventilations. The median reversed-airflow volume was 61 mL [42-80] per episode. Median ventilation rate was 14 breaths/min [13-16], gross inspiratory tidal volume 324 mL [305-345], minute ventilation 4.8 L/min [3.8-5.9], and peak inspiratory pressure 46 cmH2O [40-52]. CONCLUSION: Reversed airflow occurred frequently during asynchronous volume-controlled mechanical ventilation with the Oxylog 3000 in intubated out-of-hospital cardiac arrest patients receiving continuous manual chest compressions. Its physiological and clinical implications require further investigation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers