Comparison of delivery room wrist versus earlobe pulse oximetry in newborns: A randomized controlled trial.
Sushil Kumar, Kirti Naranje, Anita Singh, Akanksha Verma, Abhishek Paul, Abhijeet Roy, Prabhakar Mishra
Department of Neonatology, and. · Department of Neonatology, and. Electronic address: drkirtinaranje@gmail.com.
Key points
From the paper's conclusion- Time to reliable signal acquisition after probe placement did not differ between the earlobe and wrist. Further studies using neonatal-specific ear probes are warranted.
Abstract
OBJECTIVE: Rapid acquisition of reliable pulse oximetry signals in delivery room is challenging due to transitional circulation, low peripheral perfusion, motion artifact, vernix, and skin edema. This randomized controlled trial compared right earlobe and right wrist pulse oximetry to determine differences in time to reliable signal acquisition. METHODS: Pregnant women at ≥34 weeks gestation were randomized before delivery. Pulse oximetry probe was applied to either the right earlobe or right wrist immediately after birth using sensor-to-oximeter-first technique with Masimo® SET® rainbow® Radical-7® CO-Oximeter®. The primary outcome was time from completion of sensor application to reliable display of oxygen saturation and heart rate. Secondary outcomes included time from birth to start of sensor application, sensor application time, time from birth to reliable signal, perfusion index, and number of probe reapplications. RESULTS: Ninety-six neonates were randomized, with 48 in each group. Time from completion of sensor application to reliable signal was similar between ear and wrist groups (67.1±41.4 vs 74.5±48.2 seconds; mean difference -7.4 seconds; 95% CI -25.6 to 10.8; P=0.42). Sensor application time was shorter in ear group (mean difference -16.3 seconds; 95% CI -17.7 to -14.9; P<0.001), resulting in shorter time from birth to reliable signal (mean difference -28.8 seconds; 95% CI -53.9 to -3.7; P=0.02). Perfusion index was lower, and reapplication rates were higher in ear group. CONCLUSION: Time to reliable signal acquisition after probe placement did not differ between the earlobe and wrist. Further studies using neonatal-specific ear probes are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Gentleness and Reapplication Between Two Pulse Oximetry Probes in Healthy Adults in a Laboratory Setting.Medical devices (Auckland, N.Z.) · 2026
- Validating a Wearable Bluetooth Oximeter for Infants in the Neonatal Intensive Care Unit.Journal of paediatrics and child health · 2026
- Effects of paternal and maternal voice on procedural pain and physiological responses during arterial blood sampling in preterm infants in a neonatal intensive care unit: a three-arm randomized controlled trial.Intensive & critical care nursing · 2026
- Update on neonatal pulse oximetry: A narrative review.Seminars in fetal & neonatal medicine · 2026
- Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.Journal of clinical monitoring and computing · 2026
- Umbilical Artery Doppler Signal Loss After Vaginal Birth: Reliability and Gestational-Age DependenceReproductive Medicine · 2026