Umbilical Artery Doppler Signal Loss After Vaginal Birth: Reliability and Gestational-Age Dependence
Kubra Sevim Pehlivan, Ezgi Gungor, Muzaffer Enes Pehlivan, Aysegul Ciydem, Kursat Oguzhanoglu, Ali Cetin
Key points
From the paper's conclusion- Conclusions: The first sustained loss of the umbilical artery Doppler signal can be timed reproducibly from a recording and occurs later with increasing gestational maturity, so a fixed clamping interval falls at different points of this time course in preterm and term newborns.
Abstract
Background/Objectives: Cord clamping guidance relies on a fixed interval or on subjective cessation of cord pulsation. The umbilical artery carries blood from the neonate towards the placenta, and the moment its Doppler signal is first lost has rarely been timed directly. We assessed its reproducibility and its variation with gestational age. Methods: In this prospective single-centre study, 200 women with singleton vaginal deliveries at 34 to 41 weeks (100 late preterm, 100 term) were enrolled consecutively. An 8 MHz continuous-wave vascular Doppler was held over an umbilical artery from complete delivery until the signal was absent beyond 3 s, when the cord was clamped. Sixty randomly selected recordings were re-scored offline by a blinded second observer and the operator. Results: The time to first sustained signal loss (UAFCT) was 39.9 ± 10.8 s in preterm and 60.6 ± 11.2 s in term births (difference 20.8 s, 95% CI 17.7 to 23.8; Cohen d = 1.89). UAFCT rose with gestational age (adjusted β = 6.10 s per week, 95% CI 5.23 to 6.97). Intra- and inter-observer intraclass correlation coefficients were 0.95 (95% CI 0.92 to 0.97) and 0.94 (0.90 to 0.96), with limits of agreement of about ±10 s. At 30 s, a signal persisted in 81% of preterm and all term newborns. Conclusions: The first sustained loss of the umbilical artery Doppler signal can be timed reproducibly from a recording and occurs later with increasing gestational maturity, so a fixed clamping interval falls at different points of this time course in preterm and term newborns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Umbilical cord clamping timing: Results of a quality improvement program.Archivos argentinos de pediatria · 2026
- Mode‐specific fetal heart rate signal dropout as a marker of perinatal asphyxia: A multicenter observational study using causal machine learning methodsInternational Journal of Gynecology & Obstetrics · 2026
- Effect of intact cord resuscitation versus conventional cord clamping on clinical outcomes in very preterm neonates: a randomized controlled trial from Eastern India.European journal of pediatrics · 2026
- Interobserver and intraobserver variability of fetal and maternal Doppler measurements: systematic review and meta-analysis.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026
- Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed-wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study.Acta obstetricia et gynecologica Scandinavica · 2026
- Comparison of delivery room wrist versus earlobe pulse oximetry in newborns: A randomized controlled trial.Resuscitation · 2026