Graduate student, Department of Biomedical Engineering, School of Architecture and Environment, Sichuan University, Chengdu, PR China; and Graduate student, Sichuan University Yibin Park, Yibin, PR China. · Graduate student, Department of Mechanics, School of Architecture and Environment, Sichuan University, Chengdu, PR China; and Graduate student, Sichuan University Yibin Park, Yibin, PR China.

Key points

From the paper's conclusion
  • The Half-C shield provided biomechanical advantages by reducing peak stress and moderating strain distribution, indicating better mechanical performance than the classic shield and supporting its use in 2-tooth restorations.

Abstract

STATEMENT OF PROBLEM: The socket shield technique (SST) has demonstrated benefits in preserving esthetic outcomes. However, the biomechanical behavior associated with its application in multiple adjacent implant restorations remains unclear. PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical influence of classic and Half-C shield designs in bilateral maxillary central incisor and combined central-lateral incisor implant restorations and to provide biomechanical evidence to support shield selection in multitooth SST applications. MATERIAL AND METHODS: A 3-dimensional model of the complete maxilla was reconstructed. Two common anterior implant restoration scenarios were simulated: bilateral central incisors and combined central-lateral incisors. Classic and Half-C shields were generated, and 8 finite element models were constructed. Time-dependent loading was applied to the crowns. Stress distributions in the implant region and strain distributions in the surrounding bone were compared. Statistical analysis was performed using a general linear model univariate procedure (α=.05). RESULTS: The Half-C shield exhibited lower overall stress and produced a more balanced strain distribution than the classic shield. Shield type and socket aspects both significantly influenced the strain in the surrounding bone (P<.001). The Half-C configuration reduced mesiodistal strain and showed synergistic stress-relieving effects when applied on both teeth. CONCLUSIONS: The Half-C shield provided biomechanical advantages by reducing peak stress and moderating strain distribution, indicating better mechanical performance than the classic shield and supporting its use in 2-tooth restorations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers