Accuracy of complete arch implant intraoral scans: A systematic review of different technique categories compared with the conventional splinted open tray method.
Junying Li, Jiayi Lu, Zhaozhao Chen, Prajakta Shreeram Kulkarni, Yu Chun Lin, Fei Liu
Clinical Associate Professor, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich. Electronic address: junying@umich.edu. · Graduate Prosthodontic Resident, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
Key points
From the paper's conclusion- In an in vitro setting, IOS-O and IOS-SA demonstrated higher accuracy than the conventional technique in short-span implant scans. In long-span implant scans, conventional techniques were more accurate than IOS-O and IOS-SA. IOS-CISP appeared to be more accurate than conventional techniques in long spans, but the evidence is limited. Studies comparing IOS-CHS and IOS-IPG with conventional approaches are insufficient.
Abstract
STATEMENT OF PROBLEM: The accuracy comparison results between a conventional impression and an intraoral scan for a complete arch implant are mixed and unclear. PURPOSE: The purpose of this systematic review was to compare the accuracy of different categories of complete arch implant intraoral scan techniques with the conventional abutment-level splinted open tray impression technique. MATERIAL AND METHODS: A comprehensive search of the PubMed, EMBASE, and Web of Science databases was conducted to identify eligible studies. Complete arch implant scan techniques were classified into 5 categories: IOS-O, regular intraoral scan only; IOS-SA, intraoral scan with scan aid; IOS-CHS, intraoral scan with horizontal scan bodies oriented toward the center of the arch to reduce scan span; IOS-CISP, intraoral scan with auxiliary structures followed by calibration with a high-accuracy scan of the auxiliary structures to correct stitching errors in the intraoral scan; IOS-IPG, intraoral photogrammetry. The accuracy outcomes were extracted and analyzed using both descriptive statistics and meta-analysis. Subgroup analyses were conducted based on short implant span (span within premolar to premolar) and long implant span (span longer than premolar to premolar). RESULTS: Twenty-three studies, including 22 in vitro studies and 1 clinical study, were included in the present systematic review. IOS-O was investigated in 22 studies, IOS-SA in 10 studies, 2 studies for IOS-CISP, 1 study for IOS-CHS, and no available study for IOS-IPG. Descriptives analysis showed that IOS-O and IOS-SA presented better accuracy than the conventional approach in short implant spans but worse accuracy in long implant spans. IOS-CISP showed better accuracy than the conventional approach in long implant spans. Meta-analysis also showed that IOS-O and IOS-SA were more accurate than the conventional technique for short spans but that the conventional technique was more accurate for long implant spans. CONCLUSIONS: In an in vitro setting, IOS-O and IOS-SA demonstrated higher accuracy than the conventional technique in short-span implant scans. In long-span implant scans, conventional techniques were more accurate than IOS-O and IOS-SA. IOS-CISP appeared to be more accurate than conventional techniques in long spans, but the evidence is limited. Studies comparing IOS-CHS and IOS-IPG with conventional approaches are insufficient.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of complete-arch implant impressions obtained with intraoral scanning, calibrated intraoral scan protocol, extraoral and intraoral photogrammetry, and conventional impression techniques: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy comparisons of intraoral scanning, stereophotogrammetry, and reverse scanning techniques.The Journal of prosthetic dentistry · 2026
- Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring-Based Calibrated Framework: An In Vivo Study.Clinical oral implants research · 2026
- Effect of Non-Splinting Techniques and Non-Calibrated Implant Scan Body Systems on the Accuracy of Complete-Arch Implant Scans: A Comparative Clinical Study.Clinical oral implants research · 2026