Widening MR-only radiotherapy to patients with hip implants through deep learning-based synthetic CT generation.
Nico Camillo Zala, Mariia Lapaeva, Manuel Günther, Nicolaus Andratschke, Matthias Guckenberger, Stephanie Tanadini-Lang, Riccardo Dal Bello
Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland. · Department of Informatics, University of Zurich, Zurich, Switzerland.
Key points
From the paper's conclusion- These findings indicate that DL networks, specifically Pix2Pix, are capable of generating accurate pelvic sCTs for patients with hip implants, supporting further development of MR-only radiotherapy workflows for previously challenging anatomies.
Abstract
BACKGROUND AND PURPOSE: MR-based synthetic CT (sCT) generation has enabled MR-only workflows and reached clinical application for specific sites. However, most studies have excluded patients with metal implants due to signal loss and metal-induced artifacts. In this study, we evaluate the feasibility of using deep learning (DL) methods to generate sCT images from T1 Dixon MR images in patients with hip implants, expanding the applicability of MR-only radiotherapy. MATERIALS AND METHODS: A retrospective analysis included 20 patients with pelvic tumors and total hip replacements, divided into 16 training (hip-implant-only dataset) and 4 test cases. Additionally, 16 implant-free cases were added to the training set for a mixed-dataset experiment to evaluate the impact of additional data on sCT quality. A Pix2Pix generative adversarial network was trained on 2D axial MR-CT pairs, and both image similarity and dosimetric differences, including dose-volume histogram (DVH) deviations and gamma index, were assessed. RESULTS: The generated sCT closely matched the CT, with DL models demonstrating promise in reconstructing both soft tissue and hip implants despite MR signal loss. For the best-performing investigated models, all mean DVH dose differences were below 0.5% with no outliers exceeding clinically acceptable limits of 2%, and mean 1%/1 mm gamma pass rates exceeded 98%. Although the mixed-dataset configuration exhibited lower standard deviations, no statistically significant differences were observed. CONCLUSIONS: These findings indicate that DL networks, specifically Pix2Pix, are capable of generating accurate pelvic sCTs for patients with hip implants, supporting further development of MR-only radiotherapy workflows for previously challenging anatomies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical implementation of deep learning-based synthetic CT for MRI-only volumetric modulated arc therapy in head and neck and pelvic cancer patientsRadiation Oncology · 2025
- Application of synthetic computed tomography based on a deep learning model in pelvic radiotherapy planning: A feasibility study.Journal of applied clinical medical physics · 2026
- Magnetic Resonance Only Planning Validation Using Synthetic CT by MVisionVCU Scholars Compass (Virginia Commonwealth University) · 2026
- Generative structure-guided denoising diffusion probabilistic model for MR to CT image synthesis in radiotherapy planning.Physics in medicine and biology · 2026
- MRI-only workflow for preclinical ion beam therapy: Deep-learning-based synthetic CT generation from ultra-high-field small animal MRI.Zeitschrift fur medizinische Physik · 2026
- Skull-Base Synthetic CT from Brain MRI: Development, Independent-Center Validation, and Radiologist Evaluation.Journal of imaging informatics in medicine · 2026