Journal of imaging informatics in medicine

Skull-Base Synthetic CT from Brain MRI: Development, Independent-Center Validation, and Radiologist Evaluation.

Mahbod Issaiy, Shahriar Kolahi, Diana Zarei, Kavous Firouznia, Aysa Karimi, Hossein Ghanaati

Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran. · Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran. shahriar.kolahi@gmail.com.

Observational · n=43

Key points

From the paper's conclusion
  • We developed and evaluated a deep learning pipeline for skull-base synthetic computed tomography (sCT) generation from routine non-contrast T1-weighted and T2-weighted brain magnetic resonance imaging (MRI), focusing on clinically relevant bony anatomy for neurosurgical and radiotherapy workflows.

Abstract

We developed and evaluated a deep learning pipeline for skull-base synthetic computed tomography (sCT) generation from routine non-contrast T1-weighted and T2-weighted brain magnetic resonance imaging (MRI), focusing on clinically relevant bony anatomy for neurosurgical and radiotherapy workflows. We retrospectively collected 184 manually registered T1/T2/CT triplets for training and internal validation (166/18 split) and 43 cases from a second center for independent-center validation. A three-dimensional Swin-UNETR generator was trained with bone-weighted multiscale reconstruction, perceptual, and adversarial losses. Two board-certified radiologists independently scored 16 skull-base structures, artifacts, and diagnostic acceptability on raw sCT in Hounsfield units (HU), without histogram matching; this blinded review was the primary endpoint. Acceptability was 76.7% for Rater 1 and 67.4% for Rater 2 (pooled 72.1%, cluster-robust 95% CI 58.5-82.6%), with mean structure scores from 2.67 to 4.85 out of 5. Raw sCT showed limited absolute HU calibration (global MAE 364 ± 50 HU, bone Dice 0.38 ± 0.09 ), with a compressed dynamic range in which air and soft tissue were overestimated and dense bone underestimated; histogram-matched outputs, reported as a secondary analysis, reached bone Dice 0.88 ± 0.03 and bone MAE 26.31 ± 5.03 HU. Halo artifacts were near-universal, and false-canal artifacts occurred in 21-30% of cases. The method shows promise as a radiation-free adjunct for skull-base visualization, but the present results do not support replacing dedicated CT for diagnostic, dosimetric, or physics-based applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Skull-Base Synthetic CT from Brain MRI: Development, Independent-Center Validation, and Radiologist Evaluation — Science Skim