Physics and imaging in radiation oncology

Target-volume-based prescription selection for specified adverse-effect levels in automated stereotactic radiosurgery.

Joel A Pogue, Rex Cardan, Farnaz Rahim Li, Rodney Sullivan, Natalie Viscariello, Luke Moradi, John Fiveash, Richard Popple

Department of Radiation Oncology, The University of Alabama at Birmingham, 619 19th Street South, Birmingham, AL 35249, USA.

Key points

From the paper's conclusion
  • We derived a direct isoeffect prescription dose ( D RX ) model from previously validated target-volume ( V target ) power laws for single-isocenter automated SRS.

Abstract

Automated stereotactic radiosurgery (SRS) planning produced consistent dose falloff, enabling adverse-effect-relevant isodose volumes ( IDV ) to be estimated before plan generation. We derived a direct isoeffect prescription dose ( D RX ) model from previously validated target-volume ( V target ) power laws for single-isocenter automated SRS. IDV coefficients and exponents were modelled as continuous functions of relative isodose level ( RIL ), allowing D RX to be solved from V target , desired IDV , and HyTEC brain adverse-effect dose thresholds. Across held-out levels, target-level IDV residuals had a median of 0.2%, an interquartile range of [-5.2%, +7.0%], and a 95% interval of [-12.8%, +27.0%].

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers