In silico assessment of out-of-field dose in multiple brain metastases stereotactic radiosurgery.
Godfrey Mukwada, Divya Rattanpal, Pejman Rowshanfarzad, Martin A Ebert
Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, WA, 6009, Australia. Godfrey.mukwada@health.wa.gov.au. · Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, WA, 6009, Australia.
Key points
From the paper's conclusion- In stereotactic radiosurgery (SRS) for multiple brain metastases (MBM), there is higher out-of-field (OOF) dose contribution than that experienced in single metastasis.
Abstract
In stereotactic radiosurgery (SRS) for multiple brain metastases (MBM), there is higher out-of-field (OOF) dose contribution than that experienced in single metastasis. This study seeks to assess the impact of the introduced error in OOF dose in MBM SRS. CyberKnife Off-Centre-Ratios (OCRs) were modified by altering the measured umbra dose by an average 0.3 and 0.6% of the maximum in-field dose for 12 cones at 5 depths. An existing MATLAB Independent Dose Calculation (IDC) code was used to calculate dose at the Gross-Target-Volume (GTV) centre-of-mass (COM) and to surrounding voxels. GTV COM dose was calculated for 126 GTVs (36 patients) and dose deviations between unmodified and modified OCR were compared. Treatment plans in the Precision treatment planning system were analysed for potential causes of dose uncertainties. Up to 7.2% GTV COM dose deviation was observed for an average 0.6% change in umbra dose. Patients with many GTVs that were close to each other, with GTVs through which many beam passed or were proximal, and patients with large GTVs had higher dose deviations due to OOF dose contributions. Patients with multiple dose prescription levels (MDPLs) had larger dose deviations for GTVs with lower prescribed dose. Introducing known errors in umbra dose showed that MBM doses are impacted by OOF dose non-uniformly. OOF dose from one GTV beams can contribute significant dose to other GTVs and can be influenced by GTV-to-GTV proximity, geometrical distribution of GTVs, beam orientations, GTV sizes, and MPDLs. MBM SRS dose calculation demands accurate estimates of OOF dose.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Geometric and dosimetric effects of an automated clustering and plan optimization pipeline for multiple brain metastasis radiosurgeryJournal of Applied Clinical Medical Physics · 2026
- Impact of stereotactic radiosurgery dose on local control and radiation necrosis in metastatic brain lesions: a comparative study.Frontiers in oncology · 2026
- LINAC-based single-isocenter stereotactic radiotherapy for multiple brain metastases.Journal of radiation research · 2026
- Stereotactic Radiosurgery Dose Reduction for Patients With Brain Metastases From Non–Small Cell Lung Primary on Immunotherapy or Targeted TherapyNeurosurgery · 2026
- EP11.20 Outcomes Following Stereotactic Radiosurgery for Brain Metastases: A UK Single-Centre Retrospective Observational StudyNeuro-Oncology · 2026
- Contributions of previous whole-brain radiation therapy, cumulative intracranial tumor volume, and repeat radiosurgery to adverse radiation effects following stereotactic radiosurgery for brain metastasis.Clinical & experimental metastasis · 2026